Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

235

matching recommendations
Reset
SIC 3826 Analytical Instruments
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NL0006 # 05 Y:2017 05 2017 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,213 $0 Implemented
NL0006 # 04 Y:2017 04 2017 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,082 $4,000 Implemented
NL0006 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,100 $0 Implemented
NL0006 # 02 Y:2017 02 2017 DISTILL CONTAMINATED SOLVENTS FOR REUSE $14,999 $22,000 Implemented
NL0006 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,351 $69,750 Implemented
NC0573 # 07 Y:2016 07 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $618 $160 Not Implemented
NC0573 # 06 Y:2016 06 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $418 $75 Not Implemented
NC0573 # 05 Y:2016 05 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $219 $100 Implemented
NC0573 # 04 Y:2016 04 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $105 $200 Implemented
NC0573 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,685 $13,453 Implemented
NC0573 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,606 $76,556 Implemented
NC0573 # 01 Y:2016 01 2016 CHECK FOR ACCURACY OF UTILITY / POWER METERS $2,610 $100 Not Implemented
SU0414 # 08 Y:2016 08 2016 INSTALL OCCUPANCY SENSORS $46 $90 Not Implemented
SU0414 # 09 Y:2016 09 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,104 $2,253 Not Implemented
SU0414 # 07 Y:2016 07 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $493 $691 Implemented
SU0414 # 10 Y:2016 10 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $378 $803 Not Implemented
SU0414 # 11 Y:2016 11 2016 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $153 $359 Implemented
SU0414 # 12 Y:2016 12 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,446 $6,536 Not Implemented
SU0414 # 06 Y:2016 06 2016 REDUCE VENTILATION AIR $1,286 $1,309 Implemented
SU0414 # 05 Y:2016 05 2016 ELIMINATE/REDUCE AN OPERATION $8,880 $4,360 Not Implemented
SU0414 # 04 Y:2016 04 2016 ELIMINATE/REDUCE AN OPERATION $124 $0 Implemented
SU0414 # 03 Y:2016 03 2016 PAY UTILITY BILLS ON TIME $283 $0 Implemented
SU0414 # 02 Y:2016 02 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $699 $0 Implemented
SU0414 # 01 Y:2016 01 2016 ELIMINATE/REDUCE AN OPERATION $793 $0 Implemented
DL0162 # 02 Y:2016 02 2016 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $7,660 $0 Implemented