Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

221

matching recommendations
Reset
SIC 3826 Analytical Instruments
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0317 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $14,534 $20,294 Not Implemented
MA0317 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,949 $0 Implemented
MA0317 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,082 $2,792 Not Implemented
MA0317 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,897 $1,188 Implemented
MA0317 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $1,701 $1,440 Not Implemented
MA0317 # 06 Y:1994 06 1994 REUSE / RECYCLE/ SELL PAPER PRODUCTS $28,200 $700 Not Implemented
MA0317 # 07 Y:1994 07 1994 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,700 $0 Implemented
MA0290 # 01 Y:1993 01 1993 RECOVER AND REUSE COOLING WATER $12,463 $15,645 Implemented
MA0290 # 02 Y:1993 02 1993 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $6,283 $6,250 Implemented
MA0290 # 03 Y:1993 03 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,851 $1,190 Implemented
MA0290 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,146 $3,034 Implemented
MA0290 # 05 Y:1993 05 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,025 $110 Implemented
KU0139 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,499 $5,941 Not Implemented
KU0139 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,988 $3,000 Not Implemented
KU0139 # 03 Y:1984 03 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $818 $100 Not Implemented
KU0139 # 04 Y:1984 04 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,181 $1,600 Not Implemented
KU0139 # 05 Y:1984 05 1984 IMPROVE LUBRICATION PRACTICES $593 $500 Not Implemented
KU0139 # 06 Y:1984 06 1984 INSTALL AUTOMATIC STACK DAMPER $389 $500 Not Implemented
KU0139 # 07 Y:1984 07 1984 SHUT OFF PILOTS IN STANDBY EQUIPMENT $103 $0 Not Implemented
KU0139 # 08 Y:1984 08 1984 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $118 $0 Not Implemented
KU0139 # 09 Y:1984 09 1984 INSULATE BARE EQUIPMENT $148 $64 Not Implemented