Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 3827 | Optical Instruments And Lenses |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0641 # 02 Y:2010 | 02 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,220 | $3,400 | Not Implemented |
CO0641 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,910 | $5,160 | Not Implemented |
CO0641 # 04 Y:2010 | 04 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $4,170 | $31,500 | Not Implemented |
CO0641 # 05 Y:2010 | 05 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,610 | $2,880 | Not Implemented |
CO0641 # 06 Y:2010 | 06 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,270 | $35,500 | Not Implemented |
CO0641 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,300 | $5,160 | Not Implemented |
CO0641 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $520 | $810 | Not Implemented |
CO0641 # 09 Y:2010 | 09 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $320 | $650 | Not Implemented |
CO0641 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,720 | $410 | Not Implemented |
MA0661 # 06 Y:2010 | 06 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $2,526 | $11,040 | Implemented |
MA0661 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $260 | Implemented |
MA0661 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $707 | $110 | Implemented |
MA0661 # 03 Y:2010 | 03 | 2010 | REDUCE VENTILATION AIR | $31,319 | $17,008 | Implemented |
MA0661 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $562 | $588 | Implemented |
MA0661 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $830 | $200 | Not Implemented |
MA0660 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,601 | $19,240 | Not Implemented |
MA0660 # 05 Y:2010 | 05 | 2010 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $23,123 | $0 | Implemented |
MA0660 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,587 | $0 | Implemented |
MA0660 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,241 | $0 | Not Implemented |
MA0660 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,403 | $9,546 | Implemented |
SU0288 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,422 | $0 | Implemented |
SU0288 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,730 | $710 | Implemented |
SU0288 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,392 | $2,257 | Implemented |
SU0288 # 04 Y:2010 | 04 | 2010 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $50,239 | $171,000 | Implemented |
SU0288 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $161 | $729 | Implemented |