Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
56
matching recommendationsSIC | 384 | Medical Instruments And Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0342 # 01 Y:2012 | 01 | 2012 | INSTALL OCCUPANCY SENSORS | $220 | $925 | Not Implemented |
LE0342 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $17,500 | Implemented |
LE0342 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,098 | $1,800 | Not Implemented |
LE0342 # 14 Y:2012 | 14 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,722 | $85,000 | Implemented |
LE0342 # 13 Y:2012 | 13 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $72,444 | $410,000 | Implemented |
LE0342 # 12 Y:2012 | 12 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $22,316 | $58,200 | Not Implemented |
LE0342 # 11 Y:2012 | 11 | 2012 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $601,021 | $1,280,000 | Not Implemented |
LE0342 # 10 Y:2012 | 10 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,462 | $10,000 | Not Implemented |
LE0342 # 09 Y:2012 | 09 | 2012 | REPLACE BOILER | $225,837 | $230,000 | Implemented |
LE0342 # 08 Y:2012 | 08 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $1,008 | $675 | Implemented |
LE0342 # 07 Y:2012 | 07 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $24,116 | $60,000 | Implemented |
LE0342 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,433 | $40,000 | Implemented |
LE0198 # 05 Y:2004 | 05 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $540 | $566 | Implemented |
LE0198 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,168 | $76,950 | n/a |
LE0198 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,500 | $2,500 | Implemented |
LE0198 # 03 Y:2004 | 03 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,443 | $24,000 | Implemented |
LE0198 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $778 | $200 | Not Implemented |
LE0156 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $239 | $600 | Implemented |
LE0156 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $844 | $0 | Not Implemented |
LE0156 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $1,413 | $0 | Implemented |
LE0156 # 04 Y:2003 | 04 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,340 | $0 | Implemented |
LE0156 # 03 Y:2003 | 03 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,466 | $0 | Not Implemented |
LE0156 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,320 | $750 | Not Implemented |
LE0156 # 01 Y:2003 | 01 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $1,112 | $870 | Implemented |
HO0131 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,564 | $111,891 | Not Implemented |