Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,032
matching recommendationsSIC | 3841 | Surgical And Medical Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0292 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $911 | $900 | Implemented |
ND0292 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $301 | $208 | Implemented |
ND0292 # 08 Y:1998 | 08 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $96 | $0 | Implemented |
ND0292 # 09 Y:1998 | 09 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $59 | $350 | Implemented |
ND0292 # 10 Y:1998 | 10 | 1998 | OPTIMIZE PLANT POWER FACTOR | $4,292 | $9,475 | Implemented |
NV0085 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $464 | $200 | Implemented |
NV0085 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $219 | $196 | Implemented |
NV0085 # 03 Y:1997 | 03 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $26,223 | $6,283 | Not Implemented |
NV0085 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $400 | Implemented |
NV0085 # 05 Y:1997 | 05 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,705 | $2,850 | Implemented |
NV0085 # 06 Y:1997 | 06 | 1997 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,994 | $2,830 | Not Implemented |
NV0085 # 07 Y:1997 | 07 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,431 | $1,520 | Not Implemented |
NV0085 # 08 Y:1997 | 08 | 1997 | INSULATE BARE EQUIPMENT | $127 | $159 | Implemented |
NV0085 # 09 Y:1997 | 09 | 1997 | COVER OPEN TANKS | $937 | $188 | Implemented |
NV0085 # 10 Y:1997 | 10 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $6,250 | $500 | Not Implemented |
NV0085 # 11 Y:1997 | 11 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $1,000 | $150 | Implemented |
NV0085 # 12 Y:1997 | 12 | 1997 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $338 | $147 | Implemented |
UF0179 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,524 | $352 | Not Implemented |
UF0179 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,163 | $34,581 | Not Implemented |
UF0179 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $570 | $820 | Not Implemented |
UF0179 # 04 Y:1997 | 04 | 1997 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $2,876 | $3,700 | Not Implemented |
UF0179 # 05 Y:1997 | 05 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,421 | $8,860 | Not Implemented |
UF0179 # 06 Y:1997 | 06 | 1997 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $24,578 | $0 | Not Implemented |
UF0179 # 07 Y:1997 | 07 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,062 | $0 | Not Implemented |
KG0083 # 01 Y:1997 | 01 | 1997 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $3,168 | $400 | n/a |