Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
187
matching recommendationsSIC | 3841 | Surgical And Medical Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0333 # 01 Y:2018 | 01 | 2018 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $304,263 | $795,000 | Not Implemented |
MI0333 # 02 Y:2018 | 02 | 2018 | AIR CONDITION ONLY SPACE NECESSARY | $17,320 | $2,724 | Implemented |
MI0333 # 03 Y:2018 | 03 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,427 | $320 | Implemented |
MI0333 # 04 Y:2018 | 04 | 2018 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $7,399 | $15,000 | Implemented |
MI0333 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,026 | $13,843 | Implemented |
MI0333 # 06 Y:2018 | 06 | 2018 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $4,911 | $80 | Implemented |
MI0333 # 07 Y:2018 | 07 | 2018 | INSULATE BARE EQUIPMENT | $2,191 | $2,240 | Implemented |
MI0333 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $328 | $826 | Implemented |
UF0516 # 01 Y:2018 | 01 | 2018 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $120,914 | $400,000 | Not Implemented |
UF0516 # 02 Y:2018 | 02 | 2018 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $6,142 | $18,013 | Implemented |
UF0516 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,159 | $12,014 | Implemented |
UF0516 # 04 Y:2018 | 04 | 2018 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $200,000 | $100,000 | Not Implemented |
UF0516 # 05 Y:2018 | 05 | 2018 | MOVE PRODUCT USING MECHANICAL MEANS | $42,000 | $70,000 | Implemented |
UF0516 # 06 Y:2018 | 06 | 2018 | INSTALL EQUIPMENT TO MOVE PRODUCT | $30,207 | $5,350 | Not Implemented |
UF0516 # 07 Y:2018 | 07 | 2018 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $23,725 | $10,695 | Not Implemented |
MI0282 # 01 Y:2015 | 01 | 2015 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $23,744 | $1,120 | Not Implemented |
MI0282 # 02 Y:2015 | 02 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,822 | $10,322 | Implemented |
MI0282 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,613 | $1,660 | Implemented |
MI0282 # 04 Y:2015 | 04 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,005 | $1,220 | Not Implemented |
MI0282 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,694 | $40 | Not Implemented |
MI0282 # 06 Y:2015 | 06 | 2015 | REDUCE HEAT GAIN BY WINDOW TINTING | $3,779 | $16,060 | Not Implemented |
MI0282 # 07 Y:2015 | 07 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,378 | $40 | Implemented |
MI0282 # 08 Y:2015 | 08 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,655 | $1,080 | Implemented |
MI0282 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,303 | $5,120 | Implemented |
MI0282 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,250 | $995 | Implemented |