Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
502
matching recommendationsSIC | 3842 | Surgical Appliances And Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0434 # 10 Y:2010 | 10 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,649 | $232 | Not Implemented |
UF0434 # 11 Y:2010 | 11 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,515 | $7,701 | Not Implemented |
UF0434 # 12 Y:2010 | 12 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,125 | $2,284 | Not Implemented |
UF0434 # 13 Y:2010 | 13 | 2010 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $1,875 | $10,480 | Not Implemented |
UF0434 # 14 Y:2010 | 14 | 2010 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $11,568 | $0 | Not Implemented |
UF0434 # 15 Y:2010 | 15 | 2010 | RECYCLE FLUORESCENT LAMPS | $571 | $3,405 | Not Implemented |
DL0026 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $38,000 | $0 | Implemented |
DL0026 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,500 | $0 | Implemented |
DL0026 # 03 Y:2008 | 03 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,841 | $1,430 | Not Implemented |
DL0026 # 04 Y:2008 | 04 | 2008 | REDUCE VENTILATION AIR | $9,470 | $0 | Not Implemented |
DL0026 # 05 Y:2008 | 05 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,327 | $640 | Not Implemented |
DL0026 # 06 Y:2008 | 06 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,600 | $2,800 | Not Implemented |
DL0026 # 07 Y:2008 | 07 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $23,000 | $40,000 | Implemented |
DL0026 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,377 | $45,000 | Implemented |
MA0638 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $43,903 | $225,000 | Not Implemented |
MA0638 # 02 Y:2008 | 02 | 2008 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,075 | $56,000 | Not Implemented |
MA0638 # 03 Y:2008 | 03 | 2008 | REDUCE VENTILATION AIR | $12,360 | $2,500 | Implemented |
MA0638 # 04 Y:2008 | 04 | 2008 | IMPROVE COMBUSTION CONTROL CAPABILITY | $6,135 | $20,000 | Not Implemented |
MA0638 # 05 Y:2008 | 05 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,325 | $8,800 | Not Implemented |
MA0638 # 06 Y:2008 | 06 | 2008 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,428 | $16,500 | Not Implemented |
MA0638 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,761 | $0 | Implemented |
MA0638 # 08 Y:2008 | 08 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,670 | $3,000 | Implemented |
MA0638 # 09 Y:2008 | 09 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,488 | $2,450 | Not Implemented |
MA0638 # 10 Y:2008 | 10 | 2008 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,230 | $2,000 | Implemented |
AM0525 # 01 Y:2007 | 01 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $29,000 | $6,930 | Implemented |