Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,558

matching recommendations
Reset
SIC 39 Miscellaneous Manufacturing Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0289 # 06 Y:2000 06 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $13,480 $3,700 Not Implemented
MO0289 # 07 Y:2000 07 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $33,048 $2,000 Not Implemented
WI0380 # 01 Y:2000 01 2000 INSTALL AUTOMATIC PACKING EQUIPMENT $44,625 $68,300 Not Implemented
WI0380 # 02 Y:2000 02 2000 AUTOMATE FINISHING PROCESS $22,313 $2,000 Not Implemented
WI0380 # 03 Y:2000 03 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $6,415 $25,000 Not Implemented
WI0380 # 04 Y:2000 04 2000 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $3,068 $6,000 Not Implemented
WI0380 # 05 Y:2000 05 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $576 $0 Not Implemented
WI0380 # 06 Y:2000 06 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,960 $0 Not Implemented
WI0380 # 07 Y:2000 07 2000 DISTILL CONTAMINATED SOLVENTS FOR REUSE $1,671 $0 Not Implemented
WI0380 # 08 Y:2000 08 2000 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES $1,159 $1,000 Not Implemented
WI0380 # 09 Y:2000 09 2000 RECOVER WASTE HEAT FROM EQUIPMENT $845 $1,000 Not Implemented
WI0380 # 10 Y:2000 10 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $532 $0 Not Implemented
WI0380 # 11 Y:2000 11 2000 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $214 $1,020 Not Implemented
MO0280 # 01 Y:2000 01 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,311 $3,565 Implemented
MO0280 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $631 $175 Implemented
MO0280 # 03 Y:2000 03 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $909 $80 Implemented
MO0280 # 04 Y:2000 04 2000 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $194 $120 Implemented
MO0280 # 05 Y:2000 05 2000 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $540 $0 Not Implemented
MO0280 # 06 Y:2000 06 2000 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $10,800 $624 Not Implemented
MO0280 # 07 Y:2000 07 2000 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $12,820 $3,700 Not Implemented
MO0279 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $508 $1,251 Implemented
MO0279 # 02 Y:2000 02 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $988 $1,945 Not Implemented
MO0279 # 03 Y:2000 03 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $119 $88 Implemented
MO0279 # 04 Y:2000 04 2000 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,280 $4,500 Not Implemented
MO0279 # 05 Y:2000 05 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $124 $276 Not Implemented