IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,558

matching recommendations
Reset
SIC 39 Miscellaneous Manufacturing Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0403 # 06 Y:1990 06 1990 INSTALL SET-BACK TIMERS $532 $0 Implemented
TN0403 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $742 $236 Implemented
TN0403 # 08 Y:1990 08 1990 IMPROVE LUBRICATION PRACTICES $322 $180 Not Implemented
TN0403 # 09 Y:1990 09 1990 KEEP LAMPS AND REFLECTORS CLEAN $303 $963 Not Implemented
TN0403 # 10 Y:1990 10 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $161 $90 Implemented
UD0308 # 01 Y:1990 01 1990 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $13,703 $1,500 Not Implemented
UD0308 # 02 Y:1990 02 1990 TREAT AND REUSE RINSE WATERS $5,588 $2,000 Not Implemented
UD0308 # 03 Y:1990 03 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,831 $0 Not Implemented
UD0308 # 04 Y:1990 04 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,904 $900 Not Implemented
UD0308 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $861 $1,050 Not Implemented
OK0304 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $880 $355 Implemented
OK0304 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $805 $135 Implemented
OK0304 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $224 $0 Implemented
OK0304 # 04 Y:1990 04 1990 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $10,140 $17,000 Not Implemented
OK0304 # 05 Y:1990 05 1990 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,151 $1,200 Implemented
TN0384 # 01 Y:1989 01 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,074 $22,940 Implemented
TN0384 # 02 Y:1989 02 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $41,715 $16,000 Implemented
TN0384 # 03 Y:1989 03 1989 REPAIR AND ELIMINATE STEAM LEAKS $3,266 $550 Implemented
TN0384 # 04 Y:1989 04 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $2,833 $826 Implemented
TN0384 # 05 Y:1989 05 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,972 $750 Implemented
TN0384 # 06 Y:1989 06 1989 KEEP LAMPS AND REFLECTORS CLEAN $13,017 $9,388 Implemented
TN0384 # 07 Y:1989 07 1989 IMPROVE LUBRICATION PRACTICES $3,004 $0 Not Implemented
TN0384 # 08 Y:1989 08 1989 INSTALL SET-BACK TIMERS $865 $1,300 Implemented
TN0384 # 09 Y:1989 09 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $87 $180 Implemented
RU0063 # 01 Y:1989 01 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,103 $0 Implemented