IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

632

matching recommendations
Reset
SIC 394 Toys And Sporting Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0268 # 10 Y:1999 10 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $186 $0 Implemented
ME0268 # 11 Y:1999 11 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $82 $100 Not Implemented
ME0268 # 12 Y:1999 12 1999 PAY BILLS ON TIME TO AVOID LATE FEES $49 $0 Implemented
OR0343 # 01 Y:1999 01 1999 AUTOMATE FINISHING PROCESS $290,000 $165,000 Not Implemented
OR0343 # 02 Y:1999 02 1999 MODIFY CURRENT INCENTIVE PROGRAM $45,000 $23,000 Implemented
OR0343 # 03 Y:1999 03 1999 AUTOMATE FINISHING PROCESS $39,300 $32,000 Not Implemented
OR0343 # 04 Y:1999 04 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $37,500 $50,000 Implemented
OR0343 # 05 Y:1999 05 1999 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $17,775 $250 Not Implemented
OR0343 # 06 Y:1999 06 1999 UPGRADE CONTROLS ON COMPRESSORS $1,746 $0 Not Implemented
OR0343 # 07 Y:1999 07 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $403 $0 Not Implemented
OR0343 # 08 Y:1999 08 1999 OPTIMIZE PLANT POWER FACTOR $360 $1,000 Not Implemented
OR0343 # 09 Y:1999 09 1999 RECYCLE CLEANING SOLVENT AND REUSE $4,540 $6,000 Not Implemented
UF0222 # 01 Y:1999 01 1999 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $5,948 $40 Not Implemented
UF0222 # 02 Y:1999 02 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,084 $5,604 Implemented
UF0222 # 03 Y:1999 03 1999 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,102 $5,000 Not Implemented
UF0222 # 04 Y:1999 04 1999 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $4,202 $14,000 Not Implemented
UF0222 # 05 Y:1999 05 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,615 $0 Implemented
UF0222 # 06 Y:1999 06 1999 CLEAR AND RENT EXISTING SPACE $21,236 $2,240 Not Implemented
UF0222 # 07 Y:1999 07 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $6,070 $0 Implemented
SD0209 # 01 Y:1998 01 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $177,242 $44,000 Not Implemented
SD0209 # 02 Y:1998 02 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,718 $2,500 Not Implemented
SD0209 # 03 Y:1998 03 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,717 $1,000 Not Implemented
SD0209 # 04 Y:1998 04 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,228 $0 Implemented
SD0209 # 05 Y:1998 05 1998 USE A RAG RECYCLE SERVICE $10,318 $1,200 Implemented
SD0209 # 06 Y:1998 06 1998 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $331,304 $21,000 Not Implemented