Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
77
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0517 # 06 Y:2006 | 06 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,470 | $390 | Implemented |
AM0517 # 08 Y:2006 | 08 | 2006 | USE SYNTHETIC LUBRICANT | $8,900 | $0 | Implemented |
AM0517 # 09 Y:2006 | 09 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $8,100 | $500 | Implemented |
AM0517 # 10 Y:2006 | 10 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,800 | $0 | Implemented |
AM0517 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $10,440 | $85 | Implemented |
TA0006 # 01 Y:2001 | 01 | 2001 | INSTALL AUTOMATIC PACKING EQUIPMENT | $89,376 | $40,000 | n/a |
TA0006 # 07 Y:2001 | 07 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $100 | $3 | Not Implemented |
TA0006 # 06 Y:2001 | 06 | 2001 | INSTALL OCCUPANCY SENSORS | $114 | $124 | Not Implemented |
TA0006 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $450 | $35 | Implemented |
TA0006 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,518 | $0 | Implemented |
TA0006 # 03 Y:2001 | 03 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,060 | $367 | Implemented |
TA0006 # 02 Y:2001 | 02 | 2001 | COMBINE UTILITY METERS | $9,444 | $19,000 | Implemented |
AM0361 # 08 Y:2000 | 08 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $430 | $120 | n/a |
AM0361 # 07 Y:2000 | 07 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $100 | n/a |
AM0361 # 06 Y:2000 | 06 | 2000 | DISCONNECT BALLASTS | $1,930 | $300 | n/a |
AM0361 # 05 Y:2000 | 05 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $4,274 | $0 | n/a |
AM0361 # 04 Y:2000 | 04 | 2000 | DISCONNECT BALLASTS | $4,920 | $600 | n/a |
AM0361 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $20,600 | $41,200 | n/a |
AM0361 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $30,000 | $2,905 | n/a |
AM0361 # 01 Y:2000 | 01 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $576,720 | $201,440 | n/a |
AM0017 # 01 Y:1988 | 01 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,970 | $190 | Implemented |
AM0017 # 08 Y:1988 | 08 | 1988 | INSULATE BARE EQUIPMENT | $359 | $1,670 | Implemented |
AM0017 # 07 Y:1988 | 07 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $849 | $3,033 | Implemented |
AM0017 # 05 Y:1988 | 05 | 1988 | INSTALL SET-BACK TIMERS | $550 | $0 | Implemented |
AM0017 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $875 | $300 | Implemented |