Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
52
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0602 # 02 Y:2000 | 02 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,001 | $10,500 | Not Implemented |
OK0602 # 08 Y:2000 | 08 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,333 | $0 | Not Implemented |
OK0602 # 07 Y:2000 | 07 | 2000 | INSTALL EQUIPMENT TO MOVE PRODUCT | $122,640 | $200,000 | Not Implemented |
OK0602 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,151 | $14,545 | Implemented |
OK0602 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $276 | $1,620 | Not Implemented |
OK0602 # 04 Y:2000 | 04 | 2000 | INSTALL SKYLIGHTS | $9,262 | $5,460 | Not Implemented |
OK0602 # 03 Y:2000 | 03 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $26,183 | $35,000 | Not Implemented |
OK0602 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT TO MOVE PRODUCT | $229,950 | $32,400 | Not Implemented |
HO0236 # 08 Y:2000 | 08 | 2000 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $1,912 | $5,880 | n/a |
HO0236 # 12 Y:2000 | 12 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $175 | $500 | n/a |
HO0236 # 11 Y:2000 | 11 | 2000 | METER WASTE WATER | $1,000 | $250 | n/a |
HO0236 # 10 Y:2000 | 10 | 2000 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $419,000 | $30,000 | n/a |
HO0236 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $1,160 | $335 | n/a |
HO0236 # 07 Y:2000 | 07 | 2000 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $7,650 | $5,000 | n/a |
HO0236 # 06 Y:2000 | 06 | 2000 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $985 | $250 | n/a |
HO0236 # 05 Y:2000 | 05 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,374 | $20,000 | n/a |
HO0236 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,167 | $120 | n/a |
HO0236 # 01 Y:2000 | 01 | 2000 | INSTALL OCCUPANCY SENSORS | $3,159 | $2,800 | n/a |
HO0236 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $332 | $400 | n/a |
HO0236 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $402 | $15 | n/a |
OD0154 # 04 Y:2000 | 04 | 2000 | USE SYNTHETIC LUBRICANT | $158 | $13 | Not Implemented |
OD0154 # 05 Y:2000 | 05 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,218 | $150 | Not Implemented |
OD0154 # 06 Y:2000 | 06 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,218 | $135 | Not Implemented |
OD0154 # 07 Y:2000 | 07 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $70 | $0 | Not Implemented |
OD0154 # 08 Y:2000 | 08 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $155 | $20 | Not Implemented |