IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

24

matching recommendations
Reset
SIC 3993 Signs And Advertising Specialities
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0454 # 08 Y:2010 08 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $201 $150 Implemented
IA0454 # 07 Y:2010 07 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,152 $300 Implemented
IA0454 # 06 Y:2010 06 2010 RECOVER WASTE HEAT FROM EQUIPMENT $980 $400 Implemented
IA0454 # 05 Y:2010 05 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,229 $300 Implemented
IA0454 # 04 Y:2010 04 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $218 $20 Not Implemented
IA0454 # 03 Y:2010 03 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,363 $20 Not Implemented
IA0454 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $1,365 $1,560 Implemented
IA0454 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,680 $5,214 Implemented
DS0122 # 05 Y:1998 05 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $433 $88 Implemented
DS0122 # 08 Y:1998 08 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $20,218 $77,000 Not Implemented
DS0122 # 07 Y:1998 07 1998 INCREASE USE OF AUTOMATION $91,520 $15,000 Not Implemented
DS0122 # 06 Y:1998 06 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,118 $4,750 Not Implemented
DS0122 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $373 $26 Implemented
DS0122 # 03 Y:1998 03 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,446 $72 Implemented
DS0122 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $398 $250 Implemented
DS0122 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,240 $11,085 Not Implemented
DS0001 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,990 $12,650 Not Implemented
DS0001 # 08 Y:1994 08 1994 USE RADIANT HEATER FOR SPOT HEATING $9,150 $34,800 Not Implemented
DS0001 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $690 Not Implemented
DS0001 # 06 Y:1994 06 1994 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $4,760 $44,950 Not Implemented
DS0001 # 05 Y:1994 05 1994 INSTALL STORM WINDOWS AND DOORS $740 $20 Not Implemented
DS0001 # 04 Y:1994 04 1994 INSTALL STORM WINDOWS AND DOORS $1,130 $8,200 Not Implemented
DS0001 # 03 Y:1994 03 1994 INSTALL STORM WINDOWS AND DOORS $140 $280 Not Implemented
DS0001 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $70 $120 Not Implemented