ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0213 # 02 Y:2019 | 02 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,647 | $100 | Not Implemented |
UA0213 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,484 | $31,859 | Not Implemented |
UA0213 # 05 Y:2019 | 05 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,067 | $30,000 | Not Implemented |
UA0213 # 06 Y:2019 | 06 | 2019 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,399 | $4,370 | Not Implemented |
OK1011 # 08 Y:2019 | 08 | 2019 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $18,744 | $35,736 | Not Implemented |
OK1011 # 02 Y:2019 | 02 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,528 | $8,106 | Not Implemented |
OK1011 # 05 Y:2019 | 05 | 2019 | OPTIMIZE PLANT POWER FACTOR | $13,080 | $57,161 | Not Implemented |
OK1011 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,176 | $71,250 | Implemented |
OK1011 # 07 Y:2019 | 07 | 2019 | INSTALL SET-BACK TIMERS | $480 | $240 | Not Implemented |
OK1011 # 06 Y:2019 | 06 | 2019 | INSULATE BARE EQUIPMENT | $5,110 | $63 | Not Implemented |
OK1011 # 09 Y:2019 | 09 | 2019 | ADJUST / MAINTAIN FORK LIFT TRUCKS FOR MOST EFFICIENT OPERATION | $1,628 | $0 | Implemented |
OK1011 # 01 Y:2019 | 01 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,499 | $1,898 | Implemented |
OK1011 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,937 | $15,573 | Implemented |
BD0438 # 16 Y:2013 | 16 | 2013 | INSTALL OCCUPANCY SENSORS | $159 | $32 | Implemented |
BD0438 # 15 Y:2013 | 15 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $286 | $325 | Implemented |
BD0438 # 14 Y:2013 | 14 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $674 | $550 | Implemented |
BD0438 # 13 Y:2013 | 13 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $10,546 | $30,000 | Implemented |
BD0438 # 12 Y:2013 | 12 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,591 | $25 | Implemented |
BD0438 # 11 Y:2013 | 11 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $14,811 | $30,000 | Not Implemented |
BD0438 # 10 Y:2013 | 10 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,975 | $34,500 | Implemented |
BD0438 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $27,466 | $20,000 | Implemented |
BD0438 # 05 Y:2013 | 05 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $47,432 | $30 | Implemented |
BD0438 # 04 Y:2013 | 04 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $52,832 | $150,000 | Implemented |
BD0438 # 03 Y:2013 | 03 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $63,332 | $57,300 | Implemented |
BD0438 # 02 Y:2013 | 02 | 2013 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $77,861 | $384,000 | Not Implemented |