Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,747
matching recommendationsSIC | 495 | Sanitary Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2413 # 03 Y:2024 | 03 | 2024 | LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT | $20,435 | $58,800 | n/a |
UW2413 # 06 Y:2024 | 06 | 2024 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,582 | $7,250 | n/a |
UW2413 # 01 Y:2024 | 01 | 2024 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $8,896 | $25,250 | n/a |
DL0243 # 01 Y:2024 | 01 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,211 | $64,000 | n/a |
DL0243 # 02 Y:2024 | 02 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,139 | $51,000 | n/a |
DL0243 # 03 Y:2024 | 03 | 2024 | ELIMINATE/REDUCE AN OPERATION | $2,346 | $520 | n/a |
MUWT06 # 09 Y:2024 | 09 | 2024 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,478 | $6,690 | n/a |
MUWT06 # 07 Y:2024 | 07 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,231 | $0 | n/a |
MUWT06 # 03 Y:2024 | 03 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20 | $20 | n/a |
MUWT06 # 05 Y:2024 | 05 | 2024 | INSTALL OCCUPANCY SENSORS | $1,139 | $563 | n/a |
MUWT06 # 02 Y:2024 | 02 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $106 | $0 | n/a |
MUWT06 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,226 | $5,494 | n/a |
MUWT06 # 08 Y:2024 | 08 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,263 | $0 | n/a |
MUWT06 # 01 Y:2024 | 01 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $669 | $4,646 | n/a |
MUWT06 # 04 Y:2024 | 04 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,582 | $8,363 | n/a |
MUWT06 # 10 Y:2024 | 10 | 2024 | PAY BILLS ON TIME TO AVOID LATE FEES | $7,951 | $0 | n/a |
OR0797 # 05 Y:2024 | 05 | 2024 | INSTALL WIND POWERED ELECTRIC GENERATOR | $5,114 | $43,821 | n/a |
OK1126 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $9,344 | $71,615 | n/a |
OR0797 # 01 Y:2024 | 01 | 2024 | USE EXISTING DAM TO GENERATE ELECTRICITY | $4,211 | $17,825 | n/a |
OR0797 # 06 Y:2024 | 06 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $43,815 | $607,740 | n/a |
OR0797 # 04 Y:2024 | 04 | 2024 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,405 | $16,073 | n/a |
OK1126 # 03 Y:2024 | 03 | 2024 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $5,416 | $1,662 | n/a |
OR0797 # 02 Y:2024 | 02 | 2024 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,639 | $227 | n/a |
OK1126 # 06 Y:2024 | 06 | 2024 | OPTIMIZE PLANT POWER FACTOR | $634 | $5,625 | n/a |