IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,634

matching recommendations
Reset
SIC 4952 Sewerage Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NL0030 # 03 Y:2019 03 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $119 $421 Implemented
MZ0267 # 01 Y:2019 01 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,711 $4,573 Implemented
MZ0267 # 02 Y:2019 02 2019 USE PHOTOCELL CONTROLS $1,079 $410 Not Implemented
MZ0267 # 03 Y:2019 03 2019 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $53,575 $240,000 Implemented
MZ0267 # 04 Y:2019 04 2019 RECOVER AND REUSE COOLING WATER $15,813 $73,900 Implemented
MZ0267 # 05 Y:2019 05 2019 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $866 $0 Not Implemented
OK1006 # 01 Y:2019 01 2019 OPTIMIZE PLANT POWER FACTOR $3,856 $17,056 Implemented
OK1006 # 02 Y:2019 02 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,072 $9,350 Implemented
OK1006 # 03 Y:2019 03 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,709 $2,600 Not Implemented
OK1006 # 04 Y:2019 04 2019 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $262 $1,320 Not Implemented
OK1006 # 05 Y:2019 05 2019 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $392 $155 Implemented
OK1006 # 06 Y:2019 06 2019 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $341 $0 Implemented
IP0115 # 01 Y:2019 01 2019 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $1,898 $1,950 Implemented
IP0115 # 02 Y:2019 02 2019 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $188 $500 Implemented
IP0115 # 03 Y:2019 03 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,936 $6,650 Implemented
OK1005 # 01 Y:2019 01 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $127,275 $96,138 Not Implemented
OK1005 # 02 Y:2019 02 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,747 $27,232 Not Implemented
OK1005 # 03 Y:2019 03 2019 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,742 $13,761 Not Implemented
OK1005 # 04 Y:2019 04 2019 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,674 $34,500 Not Implemented
OK1005 # 05 Y:2019 05 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59,363 $100,260 Not Implemented
OK1005 # 06 Y:2019 06 2019 OPTIMIZE PLANT POWER FACTOR $20,771 $24,531 Not Implemented
OK1005 # 07 Y:2019 07 2019 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,218 $5,291 Not Implemented
OK1005 # 08 Y:2019 08 2019 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,015 $548 Not Implemented
OK1005 # 09 Y:2019 09 2019 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $913 $0 Not Implemented
OK1005 # 10 Y:2019 10 2019 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,469 $300 Not Implemented