Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

34

matching recommendations
Reset
SIC 505 Metals And Minerals, Except Petroleum
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0217 # 06 Y:2019 06 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,967 $7,769 Implemented
IC0217 # 05 Y:2019 05 2019 BURN WOOD BY-PRODUCTS FOR HEAT $5,683 $15,144 Implemented
IC0217 # 04 Y:2019 04 2019 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $62,274 $210,000 Not Implemented
IC0217 # 03 Y:2019 03 2019 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,925 $300 Implemented
IC0217 # 02 Y:2019 02 2019 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,588 $1,928 Not Implemented
IC0217 # 01 Y:2019 01 2019 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $33,543 $6,600 Implemented
IC0158 # 08 Y:2009 08 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $249 $0 Implemented
IC0158 # 07 Y:2009 07 2009 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,800 $0 Implemented
IC0158 # 06 Y:2009 06 2009 KEEP EQUIPMENT CLEAN $2,325 $0 Implemented
IC0158 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,265 $1,495 Not Implemented
IC0158 # 04 Y:2009 04 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $196 $0 Not Implemented
IC0158 # 03 Y:2009 03 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $2,880 $0 Implemented
IC0158 # 02 Y:2009 02 2009 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $177 $0 Implemented
IC0158 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $393 $686 Implemented
DL0030 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,055 $25,852 Implemented
DL0030 # 01 Y:2008 01 2008 REPLACE BOILER $5,600 $0 Not Implemented
DL0030 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,623 $5,306 Implemented
DL0030 # 06 Y:2008 06 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $120 $140 Implemented
DL0030 # 05 Y:2008 05 2008 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $10,675 $0 Implemented
DL0030 # 04 Y:2008 04 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,890 $7,500 Not Implemented
SD0411 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $92 $200 Not Implemented
SD0411 # 05 Y:2008 05 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,030 $3,394 Not Implemented
SD0411 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,111 $6,578 Not Implemented
SD0411 # 03 Y:2008 03 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,238 $2,428 Not Implemented
SD0411 # 02 Y:2008 02 2008 USE PHOTOCELL CONTROLS $5,157 $4,950 Not Implemented