Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,843

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0310 # 02 Y:1997 02 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,314 $2,000 Not Implemented
WI0310 # 03 Y:1997 03 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,061 $0 Implemented
WI0310 # 04 Y:1997 04 1997 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $601 $2,500 Not Implemented
WI0310 # 05 Y:1997 05 1997 INSULATE BARE EQUIPMENT $1,332 $397 Implemented
WI0310 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $622 $740 Not Implemented
MO0219 # 04 Y:1997 04 1997 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $3,769 $3,743 Implemented
MO0219 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $870 $0 Not Implemented
MO0219 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $297 $40 Implemented
AS0214 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $748 $771 Implemented
AS0214 # 02 Y:1997 02 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $12,440 $6,500 Not Implemented
AS0214 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $370 $60 Implemented
AS0214 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,398 $1,360 Implemented
AS0214 # 05 Y:1997 05 1997 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,384 $320 Not Implemented
AS0214 # 06 Y:1997 06 1997 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $4,898 $8,400 Not Implemented
AS0214 # 07 Y:1997 07 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,805 $901 Implemented
NV0088 # 01 Y:1997 01 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $240 $200 Implemented
NV0088 # 02 Y:1997 02 1997 INSTALL TIMERS AND/OR THERMOSTATS $6,653 $3,100 Implemented
NV0088 # 03 Y:1997 03 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $109 $39 Implemented
NV0088 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $669 $1,148 Implemented
NV0088 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $2,073 $900 Implemented
NV0088 # 06 Y:1997 06 1997 INSULATE BARE EQUIPMENT $163 $86 Implemented
ND0287 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,628 $492 Implemented
ND0287 # 02 Y:1997 02 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,921 $2,000 Not Implemented
ND0287 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $922 $400 Not Implemented
ND0287 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $838 $75 Not Implemented