Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

142,599

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0213 # 05 Y:2023 05 2023 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $639 $1,950 Not Implemented
UD1050 # 01 Y:2023 01 2023 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,383 $0 Implemented
UD1050 # 02 Y:2023 02 2023 SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS $3,723 $0 Not Implemented
UD1050 # 03 Y:2023 03 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,863 $0 Implemented
UD1050 # 04 Y:2023 04 2023 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,060 $0 Not Implemented
UD1050 # 05 Y:2023 05 2023 PREHEAT COMBUSTION AIR WITH WASTE HEAT $4,168 $0 Not Implemented
UD1050 # 06 Y:2023 06 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,940 $32,403 Implemented
TR0032 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,606 $6,302 Not Implemented
TR0032 # 02 Y:2022 02 2022 OPTIMIZE PLANT POWER FACTOR $6,520 $17,100 Not Implemented
TR0032 # 03 Y:2022 03 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $291,171 $4,331,813 Not Implemented
AM0867 # 01 Y:2023 01 2023 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $259,000 $25,200 Not Implemented
AM0867 # 03 Y:2023 03 2023 REPAIR OR REPLACE STEAM TRAPS $109,400 $10,100 Not Implemented
AM0867 # 04 Y:2023 04 2023 REDUCE EXCESSIVE BOILER BLOWDOWN $67,910 $12,000 Not Implemented
AM0867 # 05 Y:2023 05 2023 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $34,000 $10,000 Not Implemented
AM0867 # 06 Y:2023 06 2023 OPTIMIZE PLANT POWER FACTOR $23,500 $87,830 Not Implemented
WM0186 # 01 Y:2023 01 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $99,547 $82,860 Implemented
WM0186 # 02 Y:2023 02 2023 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $25,831 $10,920 Not Implemented
WM0186 # 03 Y:2023 03 2023 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,140 $5,250 Implemented
WM0186 # 04 Y:2023 04 2023 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,467 $0 Implemented
WM0186 # 05 Y:2023 05 2023 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $786 $1,537 Not Implemented
WM0186 # 06 Y:2023 06 2023 USE COMPRESSOR AIR FILTERS $643 $2,773 Not Implemented
WM0186 # 07 Y:2023 07 2023 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $230 $326 Not Implemented
UL2215 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,172 $939 Implemented
UL2215 # 02 Y:2022 02 2022 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,205 $0 Not Implemented
UL2215 # 03 Y:2022 03 2022 INSTALL OCCUPANCY SENSORS $2,134 $521 Not Implemented