Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
143,541
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0184 # 01 Y:1990 | 01 | 1990 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $7,600 | $500 | Implemented |
CO0184 # 02 Y:1990 | 02 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,500 | $4,000 | Implemented |
CO0184 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,630 | $12,700 | Not Implemented |
CO0184 # 04 Y:1990 | 04 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $8,590 | $1,300 | Implemented |
CO0184 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,320 | $3,670 | Not Implemented |
CO0184 # 06 Y:1990 | 06 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,280 | $2,100 | Implemented |
CO0184 # 07 Y:1990 | 07 | 1990 | OPTIMIZE PLANT POWER FACTOR | $18,190 | $20,700 | Not Implemented |
CO0185 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,780 | $750 | Implemented |
CO0185 # 02 Y:1990 | 02 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,370 | $13,700 | Not Implemented |
CO0185 # 03 Y:1990 | 03 | 1990 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $2,390 | $200 | Implemented |
CO0185 # 04 Y:1990 | 04 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,620 | $50 | Implemented |
CO0185 # 05 Y:1990 | 05 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,010 | $300 | Implemented |
CO0185 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $790 | $940 | Not Implemented |
CO0185 # 07 Y:1990 | 07 | 1990 | OPTIMIZE PLANT POWER FACTOR | $6,200 | $7,400 | Not Implemented |
MO0001 # 01 Y:1990 | 01 | 1990 | MODIFY DYE BECK | $30,784 | $16,000 | Implemented |
MO0001 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,122 | $2,500 | Not Implemented |
MO0001 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,351 | $900 | Implemented |
MO0001 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,805 | $750 | Implemented |
MO0001 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $375 | $137 | Implemented |
MO0001 # 06 Y:1990 | 06 | 1990 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $256 | $500 | Not Implemented |
WI0086 # 01 Y:1990 | 01 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,882 | $0 | Not Implemented |
WI0086 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,034 | $2,719 | Not Implemented |
WI0086 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,311 | $0 | Not Implemented |
WI0086 # 04 Y:1990 | 04 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,293 | $7,000 | Not Implemented |
WI0086 # 05 Y:1990 | 05 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,028 | $2,448 | Not Implemented |