Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

143,508

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0057 # 05 Y:1989 05 1989 INSTALL AUTOMATIC STACK DAMPER $1,970 $1,400 Implemented
WI0057 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $507 $500 Not Implemented
WI0057 # 07 Y:1989 07 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $271 $0 Not Implemented
WI0057 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $211 $0 Not Implemented
MA0150 # 01 Y:1989 01 1989 INSTALL SET-BACK TIMERS $5,583 $7,511 Not Implemented
MA0150 # 02 Y:1989 02 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $2,258 $3,032 Implemented
MA0150 # 03 Y:1989 03 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,394 $2,099 Implemented
MA0150 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $327 $53 Not Implemented
MA0150 # 05 Y:1989 05 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,082 $576 Not Implemented
MA0150 # 06 Y:1989 06 1989 INSTALL SET-BACK TIMERS $123 $146 Not Implemented
MA0151 # 01 Y:1989 01 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,228 $426 Not Implemented
MA0151 # 02 Y:1989 02 1989 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $1,218 $305 Not Implemented
MA0151 # 03 Y:1989 03 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $4,308 $243 Not Implemented
MA0151 # 04 Y:1989 04 1989 BURN A LESS EXPENSIVE GRADE OF FUEL $12,509 $15,150 Implemented
MA0151 # 05 Y:1989 05 1989 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,022 $593 Implemented
MA0151 # 06 Y:1989 06 1989 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $1,093 $592 Not Implemented
MA0151 # 07 Y:1989 07 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,050 $3,150 Not Implemented
UD0290 # 01 Y:1989 01 1989 COMBINE UTILITY METERS $2,104 $1,000 Implemented
UD0290 # 02 Y:1989 02 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,658 $8,000 Not Implemented
UD0290 # 03 Y:1989 03 1989 RECOVER WASTE HEAT FROM EQUIPMENT $2,035 $3,000 Not Implemented
UD0290 # 04 Y:1989 04 1989 KEEP LAMPS AND REFLECTORS CLEAN $6,394 $11,600 Implemented
UD0290 # 05 Y:1989 05 1989 REDUCE GLAZED AREAS IN BUILDINGS $22,077 $21,750 Implemented
UD0290 # 06 Y:1989 06 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,146 $465 Implemented
UD0291 # 01 Y:1989 01 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,548 $6,000 Not Implemented
UD0291 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,832 $15,000 Implemented