Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,820
matching recommendationsARC | 2 | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0216 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $766 | $750 | Not Implemented |
AS0216 # 03 Y:1998 | 03 | 1998 | DISCONNECT BALLASTS | $183 | $15 | Not Implemented |
AS0216 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,042 | $60 | Not Implemented |
AS0216 # 05 Y:1998 | 05 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $671 | $375 | Not Implemented |
AS0216 # 06 Y:1998 | 06 | 1998 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,307 | $940 | Implemented |
DS0102 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,348 | $4,800 | Implemented |
DS0102 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $602 | $180 | Implemented |
DS0102 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $438 | $985 | Not Implemented |
DS0102 # 07 Y:1998 | 07 | 1998 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $952 | $1,695 | Implemented |
SD0187 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,309 | $3,660 | Implemented |
SD0187 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,982 | $500 | Implemented |
SD0187 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,566 | $0 | Implemented |
SD0187 # 04 Y:1998 | 04 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,433 | $2,400 | Implemented |
SF0131 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,233 | $10,320 | Not Implemented |
SF0131 # 02 Y:1998 | 02 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $458 | $438 | Not Implemented |
SF0131 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,425 | $2,899 | Not Implemented |
SF0131 # 04 Y:1998 | 04 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $514 | $831 | Not Implemented |
SF0131 # 05 Y:1998 | 05 | 1998 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,954 | $4,750 | Not Implemented |
SF0131 # 06 Y:1998 | 06 | 1998 | USE PHOTOCELL CONTROLS | $3,187 | $2,250 | Not Implemented |
SF0131 # 07 Y:1998 | 07 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,535 | $370 | Not Implemented |
SF0131 # 08 Y:1998 | 08 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $1,580 | $625 | Not Implemented |
SF0131 # 09 Y:1998 | 09 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $651 | $175 | Not Implemented |
BD0102 # 01 Y:1998 | 01 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,521 | $0 | Not Implemented |
BD0102 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $1,411 | $400 | Not Implemented |
BD0102 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $474 | $800 | Not Implemented |