Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,521
matching recommendationsARC | 2. | ENERGY MANAGEMENT |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0451 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $6,320 | $4,800 | Implemented |
UM0451 # 03 Y:2014 | 03 | 2014 | REVISE SMOKE CLEANUP FROM OPERATIONS | $79,670 | $60,000 | Not Implemented |
UM0451 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $16,165 | $25,000 | Implemented |
UM0451 # 04 Y:2014 | 04 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,930 | $6,000 | Not Implemented |
DL0137 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $640 | $1,040 | Not Implemented |
DL0137 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $745 | $160 | Not Implemented |
DL0137 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,820 | $10,075 | Not Implemented |
DL0137 # 01 Y:2014 | 01 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $17,190 | $20,000 | Implemented |
DL0137 # 07 Y:2014 | 07 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,350 | $6,300 | Implemented |
DL0137 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,900 | $38,400 | Not Implemented |
DL0137 # 04 Y:2014 | 04 | 2014 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $890 | $2,220 | Not Implemented |
DL0137 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $245 | $2,280 | Not Implemented |
DL0137 # 02 Y:2014 | 02 | 2014 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $14,240 | $5,460 | Not Implemented |
DL0137 # 08 Y:2014 | 08 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $970 | $1,200 | Implemented |
DL0137 # 05 Y:2014 | 05 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,520 | $8,430 | Not Implemented |
MZ0164 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $56,600 | $384,000 | Implemented |
IP0032 # 03 Y:2014 | 03 | 2014 | USE SOLAR HEAT TO HEAT WATER | $69,019 | $314,300 | Not Implemented |
MZ0164 # 05 Y:2014 | 05 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,593 | $6,500 | Implemented |
IP0032 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,644 | $16,018 | Implemented |
UD0917 # 02 Y:2014 | 02 | 2014 | REDUCE FLUID FLOW RATES | $3,671 | $0 | Not Implemented |
MZ0164 # 01 Y:2014 | 01 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $188,887 | $0 | Implemented |
MZ0164 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,200 | $1,430 | Implemented |
MZ0164 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $1,744 | $1,500 | Not Implemented |
UD0917 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,376 | $0 | Implemented |
IP0032 # 04 Y:2014 | 04 | 2014 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,263 | $0 | Implemented |