Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

497

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0016 # 08 Y:1992 08 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $283 $536 Not Implemented
OK0379 # 03 Y:1992 03 1992 INSULATE BARE EQUIPMENT $89 $108 Implemented
OR0146 # 06 Y:1992 06 1992 INSULATE FEEDWATER TANK $157 $333 Not Implemented
OR0145 # 08 Y:1992 08 1992 INSULATE BARE EQUIPMENT $1,297 $6,740 Not Implemented
OK0377 # 01 Y:1992 01 1992 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $17,190 $35,000 Implemented
OK0375 # 03 Y:1992 03 1992 RECOVER WASTE HEAT FROM EQUIPMENT $3,604 $505 Not Implemented
CO0245 # 08 Y:1992 08 1992 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $770 $3,100 Implemented
CO0244 # 03 Y:1992 03 1992 RECOVER WASTE HEAT FROM EQUIPMENT $530 $600 Implemented
CO0244 # 07 Y:1992 07 1992 INSULATE BARE EQUIPMENT $150 $30 Implemented
CO0243 # 08 Y:1992 08 1992 USE MINIMUM SAFE OVEN VENTILATION $260 $680 Implemented
CO0243 # 09 Y:1992 09 1992 INSULATE BARE EQUIPMENT $610 $3,410 Implemented
AS0055 # 03 Y:1992 03 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,959 $10,500 Not Implemented
AS0055 # 05 Y:1992 05 1992 USE OPTIMUM THICKNESS INSULATION $727 $3,700 Not Implemented
GT0465 # 03 Y:1992 03 1992 INCREASE AMOUNT OF CONDENSATE RETURNED $7,940 $6,000 Not Implemented
IA0016 # 02 Y:1992 02 1992 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $10,600 $30,400 Not Implemented
IA0016 # 04 Y:1992 04 1992 INSULATE BARE EQUIPMENT $116 $120 Not Implemented
IA0016 # 05 Y:1992 05 1992 RECOVER WASTE HEAT FROM EQUIPMENT $2,678 $500 Not Implemented
KU0370 # 03 Y:1992 03 1992 RECOVER WASTE HEAT FROM EQUIPMENT $527 $0 Implemented
KU0371 # 03 Y:1992 03 1992 INSULATE BARE EQUIPMENT $1,732 $4,032 Not Implemented
MA0243 # 07 Y:1992 07 1992 REPAIR OR REPLACE STEAM TRAPS $785 $1 Implemented
MA0243 # 08 Y:1992 08 1992 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $365 $220 Implemented
SD0018 # 03 Y:1992 03 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,562 $120 Implemented
SD0018 # 04 Y:1992 04 1992 RECOVER WASTE HEAT FROM EQUIPMENT $1,764 $551 Implemented
SD0018 # 05 Y:1992 05 1992 RECOVER WASTE HEAT FROM EQUIPMENT $635 $729 Not Implemented
SD0019 # 03 Y:1992 03 1992 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,209 $100 Not Implemented