Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,790
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0158 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,058 | $849 | n/a |
ND0158 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,142 | $1,525 | n/a |
ND0158 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $459 | n/a |
WI0180 # 01 Y:1993 | 01 | 1993 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $17,501 | $0 | Implemented |
WI0180 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,585 | $17,728 | Not Implemented |
WI0180 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $9,793 | $3,450 | Implemented |
WI0180 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,508 | $6,708 | Implemented |
WI0180 # 05 Y:1993 | 05 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,804 | $18,262 | Implemented |
WI0180 # 09 Y:1993 | 09 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,744 | $2,800 | Not Implemented |
WI0180 # 13 Y:1993 | 13 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,451 | $3,410 | Not Implemented |
WI0180 # 14 Y:1993 | 14 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $841 | $900 | Not Implemented |
GT0492 # 07 Y:1993 | 07 | 1993 | INSTALL OCCUPANCY SENSORS | $1,450 | $630 | Not Implemented |
GT0492 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,990 | $58,000 | Implemented |
GT0492 # 09 Y:1993 | 09 | 1993 | DISCONNECT BALLASTS | $980 | $1,200 | Implemented |
SF0002 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,211 | $572 | Not Implemented |
UD0403 # 03 Y:1993 | 03 | 1993 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,873 | $202 | Implemented |
UD0403 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $532 | $250 | Implemented |
KU0398 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $0 | Implemented |
KU0398 # 08 Y:1993 | 08 | 1993 | USE PHOTOCELL CONTROLS | $835 | $400 | Not Implemented |
KU0398 # 09 Y:1993 | 09 | 1993 | INSTALL OCCUPANCY SENSORS | $769 | $1,260 | Not Implemented |
KU0397 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $800 | $4,524 | Implemented |
ND0153 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,992 | $1,262 | Implemented |
WI0179 # 01 Y:1993 | 01 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,974 | $4,960 | Not Implemented |
WI0179 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,295 | $5,659 | Not Implemented |
WI0179 # 03 Y:1993 | 03 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,270 | $0 | Implemented |