Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,717
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0064 # 02 Y:1986 | 02 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,256 | $0 | Implemented |
MA0063 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $325 | $60 | Implemented |
KU0198 # 08 Y:1986 | 08 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $562 | $124 | Implemented |
KU0199 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,919 | $6,173 | Implemented |
KU0199 # 03 Y:1986 | 03 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,330 | $100 | Implemented |
KU0199 # 04 Y:1986 | 04 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,289 | $100 | Implemented |
KU0199 # 05 Y:1986 | 05 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $906 | $34 | Implemented |
KU0200 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,229 | $14,500 | Implemented |
KU0200 # 03 Y:1986 | 03 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,694 | $0 | Implemented |
OK0195 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,989 | $500 | Implemented |
OK0196 # 03 Y:1986 | 03 | 1986 | USE RADIANT HEATER FOR SPOT HEATING | $7,663 | $36,000 | Not Implemented |
OK0197 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $817 | $782 | Implemented |
OK0197 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,696 | $2,411 | Implemented |
OK0197 # 08 Y:1986 | 08 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,916 | $249 | Implemented |
OK0198 # 04 Y:1986 | 04 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,532 | $22,000 | Not Implemented |
OK0198 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,027 | $276 | Implemented |
OK0198 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,856 | $3,272 | Implemented |
OK0199 # 01 Y:1986 | 01 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,090 | $160 | Implemented |
OK0199 # 04 Y:1986 | 04 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,727 | $5,271 | Implemented |
OK0200 # 01 Y:1986 | 01 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $1,274 | $5,000 | Not Implemented |
OK0200 # 02 Y:1986 | 02 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,679 | $4,000 | Implemented |
OK0200 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,249 | $7,000 | Not Implemented |
OK0200 # 04 Y:1986 | 04 | 1986 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $924 | $2,355 | Implemented |
OK0201 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $361 | $39 | Implemented |
OK0201 # 03 Y:1986 | 03 | 1986 | USE RADIANT HEATER FOR SPOT HEATING | $7,928 | $18,000 | Not Implemented |