Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,645
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0026 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $167 | $300 | Not Implemented |
OK0027 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $792 | $108 | Not Implemented |
OK0027 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46 | $42 | Not Implemented |
OK0021 # 06 Y:1982 | 06 | 1982 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,950 | $1,500 | Not Implemented |
OK0021 # 07 Y:1982 | 07 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $266 | $4,572 | Implemented |
OK0022 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,256 | $13,760 | Not Implemented |
OK0022 # 04 Y:1982 | 04 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,141 | $6,006 | Not Implemented |
OK0022 # 05 Y:1982 | 05 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $156 | $78 | Not Implemented |
OK0022 # 06 Y:1982 | 06 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $150 | $75 | Not Implemented |
OK0024 # 01 Y:1982 | 01 | 1982 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $3,189 | $16,389 | Not Implemented |
OK0024 # 02 Y:1982 | 02 | 1982 | INSTALL STORM WINDOWS AND DOORS | $300 | $566 | Not Implemented |
OK0024 # 03 Y:1982 | 03 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,502 | $3,500 | Not Implemented |
OK0024 # 06 Y:1982 | 06 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $386 | $90 | Not Implemented |
OK0029 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,887 | $18,833 | Not Implemented |
OK0031 # 02 Y:1982 | 02 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $927 | $1,665 | Not Implemented |
OK0031 # 04 Y:1982 | 04 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,109 | $280 | Implemented |
OK0032 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $107 | $170 | Not Implemented |
OK0032 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $168 | $400 | Not Implemented |
KU0034 # 01 Y:1982 | 01 | 1982 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $6,130 | $6,000 | Not Implemented |
KU0034 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,770 | $3,635 | Not Implemented |
KU0034 # 05 Y:1982 | 05 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $450 | $869 | Not Implemented |
KU0035 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,065 | $36,000 | Not Implemented |
KU0035 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,265 | $535 | Implemented |
KU0036 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,455 | $1,375 | Not Implemented |
KU0036 # 02 Y:1982 | 02 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $360 | $150 | Not Implemented |