Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,685
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0463 # 01 Y:2015 | 01 | 2015 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $25,698 | $10,000 | Not Implemented |
BD0463 # 02 Y:2015 | 02 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,918 | $4,000 | Not Implemented |
BD0463 # 03 Y:2015 | 03 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $6,230 | $4,800 | Not Implemented |
BD0463 # 04 Y:2015 | 04 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $828 | $40 | Not Implemented |
BD0463 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,935 | $1,800 | Not Implemented |
BD0463 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $1,747 | $1,575 | Not Implemented |
BD0463 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $748 | $25 | Not Implemented |
BD0463 # 08 Y:2015 | 08 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $439 | $800 | Not Implemented |
BD0463 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $352 | $305 | Not Implemented |
BD0463 # 10 Y:2015 | 10 | 2015 | RECYCLE CASTING SAND | $8,450 | $1,000 | Not Implemented |
BD0462 # 01 Y:2015 | 01 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $9,937 | $8,800 | Implemented |
BD0462 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,640 | $300 | Implemented |
BD0462 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,604 | $3,500 | Implemented |
BD0462 # 04 Y:2015 | 04 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $6,049 | $4,000 | Implemented |
BD0462 # 05 Y:2015 | 05 | 2015 | REPLACE BOILER | $3,962 | $7,604 | Implemented |
BD0462 # 06 Y:2015 | 06 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,511 | $1,400 | Not Implemented |
BD0462 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $861 | $975 | Not Implemented |
BD0462 # 08 Y:2015 | 08 | 2015 | INSTALL TURBULATORS | $595 | $1,160 | Not Implemented |
BD0462 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $396 | $325 | Not Implemented |
BD0462 # 10 Y:2015 | 10 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $29 | $54 | Not Implemented |
BD0462 # 11 Y:2015 | 11 | 2015 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $15,189 | $2,000 | Not Implemented |
BD0462 # 12 Y:2015 | 12 | 2015 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,464 | $6,000 | Not Implemented |
BD0462 # 13 Y:2015 | 13 | 2015 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $6,060 | $300 | Not Implemented |
BD0461 # 01 Y:2015 | 01 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $38,137 | $30,000 | Not Implemented |
BD0461 # 02 Y:2015 | 02 | 2015 | ADJUST BURNERS FOR EFFICIENT OPERATION | $11,376 | $1,000 | Implemented |