Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0406 # 09 Y:2012 | 09 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,962 | $2,736 | Not Implemented |
BD0406 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $1,808 | $1,350 | Implemented |
BD0406 # 11 Y:2012 | 11 | 2012 | INSTALL TURBULATORS | $772 | $1,500 | Implemented |
BD0406 # 12 Y:2012 | 12 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $434 | $150 | Not Implemented |
BD0406 # 13 Y:2012 | 13 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $254 | $10 | Implemented |
BD0406 # 14 Y:2012 | 14 | 2012 | RECOVER AND REUSE COOLING WATER | $15,696 | $2,200 | Not Implemented |
BD0405 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,816 | $4,065 | Not Implemented |
BD0405 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,415 | $7,299 | Implemented |
BD0405 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,286 | $15,356 | Implemented |
BD0405 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $2,161 | $1,050 | Implemented |
BD0405 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $82 | $10 | Implemented |
BD0405 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,704 | $40,000 | Implemented |
BD0404 # 01 Y:2012 | 01 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $49,969 | $32,000 | Not Implemented |
BD0404 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,392 | $76,240 | Implemented |
BD0404 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,023 | $25,000 | Not Implemented |
BD0404 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $4,130 | $8,000 | Implemented |
BD0404 # 05 Y:2012 | 05 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,137 | $20 | Implemented |
BD0404 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,573 | $1,500 | Implemented |
BD0404 # 07 Y:2012 | 07 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $1,669 | $100 | Implemented |
BD0403 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,988 | $5,268 | Implemented |
BD0403 # 02 Y:2012 | 02 | 2012 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,936 | $440 | Not Implemented |
BD0403 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,011 | $150 | Implemented |
BD0403 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $10 | Implemented |
BD0403 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $851 | $450 | Implemented |
BD0403 # 06 Y:2012 | 06 | 2012 | MINIMIZE WATER USAGE | $763 | $1,000 | Implemented |