Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0349 # 07 Y:2008 | 07 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $128,022 | $46,000 | Not Implemented |
BD0349 # 08 Y:2008 | 08 | 2008 | MINIMIZE WATER USAGE | $991 | $2,300 | Not Implemented |
BD0346 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84,447 | $2,972 | Implemented |
BD0346 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,472 | $676 | Not Implemented |
BD0346 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,548 | $4,569 | Not Implemented |
BD0346 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $1,366 | Not Implemented |
BD0346 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,385 | $10,001 | Implemented |
BD0346 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $833 | $501 | Implemented |
BD0346 # 07 Y:2008 | 07 | 2008 | REPLACE BOILER | $37,675 | $65,001 | Not Implemented |
BD0346 # 08 Y:2008 | 08 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,096 | $1,251 | Not Implemented |
BD0346 # 09 Y:2008 | 09 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $19,119 | $14,001 | Not Implemented |
BD0347 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $51,977 | $120 | Implemented |
BD0347 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $4,457 | $5,400 | Implemented |
BD0347 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,032 | $2 | Not Implemented |
BD0347 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,195 | $501 | Not Implemented |
BD0347 # 05 Y:2008 | 05 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $41,601 | $43,021 | Not Implemented |
BD0347 # 06 Y:2008 | 06 | 2008 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $898 | $2,101 | Not Implemented |
BD0347 # 07 Y:2008 | 07 | 2008 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,228 | $257 | Not Implemented |
BD0347 # 08 Y:2008 | 08 | 2008 | USE EVAPORATION TO CONCENTRATE MATERIAL | $5,997 | $7,996 | Not Implemented |
BD0343 # 01 Y:2008 | 01 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $10,631 | $12,501 | Not Implemented |
BD0343 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,924 | $6,730 | Not Implemented |
BD0343 # 03 Y:2008 | 03 | 2008 | INSTALL SKYLIGHTS | $693 | $5,713 | Not Implemented |
BD0343 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $188 | $405 | Not Implemented |
BD0343 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $788 | $788 | Not Implemented |
BD0343 # 06 Y:2008 | 06 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,874 | $9,167 | Not Implemented |