Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0270 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,396 | $480 | Not Implemented |
BD0270 # 05 Y:2004 | 05 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $4,757 | $1,000 | Not Implemented |
BD0270 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,453 | $3,500 | Not Implemented |
BD0270 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,382 | $750 | Implemented |
BD0270 # 08 Y:2004 | 08 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,173 | $75 | Implemented |
BD0270 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $1,040 | $320 | Implemented |
BD0270 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $353 | $168 | Implemented |
BD0270 # 11 Y:2004 | 11 | 2004 | MINIMIZE WATER USAGE | $3,135 | $1,320 | Not Implemented |
BD0270 # 12 Y:2004 | 12 | 2004 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $0 | $3,000 | Not Implemented |
BD0271 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,022 | $1,900 | Implemented |
BD0271 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $24,721 | $500 | Implemented |
BD0271 # 03 Y:2004 | 03 | 2004 | OPTIMIZE PLANT POWER FACTOR | $18,512 | $44,500 | Not Implemented |
BD0271 # 04 Y:2004 | 04 | 2004 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $15,124 | $6,800 | Implemented |
BD0271 # 05 Y:2004 | 05 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,880 | $20,000 | n/a |
BD0271 # 06 Y:2004 | 06 | 2004 | USE SYNTHETIC LUBRICANT | $3,573 | $320 | Implemented |
BD0271 # 07 Y:2004 | 07 | 2004 | USE SYNTHETIC LUBRICANT | $3,573 | $450 | Implemented |
BD0271 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,621 | $0 | Implemented |
BD0271 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $636 | $1,200 | Not Implemented |
BD0271 # 10 Y:2004 | 10 | 2004 | USE OPTIMUM THICKNESS INSULATION | $278 | $434 | Not Implemented |
BD0271 # 11 Y:2004 | 11 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $15,320 | $180 | Implemented |
BD0271 # 12 Y:2004 | 12 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,425 | $500 | Implemented |
BD0271 # 13 Y:2004 | 13 | 2004 | PAY BILLS ON TIME TO AVOID LATE FEES | $9,163 | $0 | Not Implemented |
BD0269 # 07 Y:2004 | 07 | 2004 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $1,363 | $340 | Implemented |
BD0269 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,601 | $731 | Implemented |
BD0269 # 09 Y:2004 | 09 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,243 | $2,000 | Implemented |