Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CI0048 # 08 Y:2025 | 08 | 2025 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,170 | $18,100 | n/a |
CI0048 # 07 Y:2025 | 07 | 2025 | USE PHOTOCELL CONTROLS | $2,640 | $2,150 | n/a |
CI0048 # 06 Y:2025 | 06 | 2025 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,445 | $1,536 | n/a |
CI0048 # 05 Y:2025 | 05 | 2025 | INSTALL OCCUPANCY SENSORS | $4,884 | $3,750 | n/a |
CI0048 # 04 Y:2025 | 04 | 2025 | INSTALL TIMERS AND/OR THERMOSTATS | $5,329 | $2,160 | n/a |
CI0048 # 03 Y:2025 | 03 | 2025 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,546 | $32,000 | n/a |
CI0048 # 02 Y:2025 | 02 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,034 | $1,595 | n/a |
CI0048 # 01 Y:2025 | 01 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $54,215 | $280,743 | n/a |
CI0046 # 04 Y:2025 | 04 | 2025 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $91,633 | $10,000 | n/a |
CI0046 # 06 Y:2025 | 06 | 2025 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,340 | $10,000 | n/a |
CI0046 # 05 Y:2025 | 05 | 2025 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $83,773 | $30,000 | n/a |
CI0046 # 03 Y:2025 | 03 | 2025 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $117,094 | $122,400 | n/a |
CI0046 # 02 Y:2025 | 02 | 2025 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $121,817 | $500,000 | n/a |
CI0046 # 01 Y:2025 | 01 | 2025 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $156,899 | $330,000 | n/a |
CI0045 # 01 Y:2025 | 01 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $360,332 | $3,128,595 | n/a |
CI0045 # 08 Y:2025 | 08 | 2025 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,247 | $910 | n/a |
CI0045 # 07 Y:2025 | 07 | 2025 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,694 | $5,000 | n/a |
CI0045 # 06 Y:2025 | 06 | 2025 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,072 | $25,000 | n/a |
CI0045 # 05 Y:2025 | 05 | 2025 | INSULATE BARE EQUIPMENT | $13,658 | $2,310 | n/a |
CI0045 # 04 Y:2025 | 04 | 2025 | USE PHOTOCELL CONTROLS | $36,786 | $6,000 | n/a |
CI0045 # 03 Y:2025 | 03 | 2025 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $75,467 | $293,581 | n/a |
CI0045 # 02 Y:2025 | 02 | 2025 | USE BATTERY STORAGE FOR DEMAND CONTROL | $118,038 | $200,000 | n/a |