IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,905

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0235 # 04 Y:1992 04 1992 USE POWER DURING OFF-PEAK PERIODS $3,390 $2,450 Implemented
CO0235 # 05 Y:1992 05 1992 INSULATE BARE EQUIPMENT $3,720 $3,860 Implemented
CO0235 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,290 $7,560 Implemented
CO0235 # 07 Y:1992 07 1992 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $585 $750 Implemented
CO0235 # 08 Y:1992 08 1992 RECOVER WASTE HEAT FROM EQUIPMENT $30,500 $60,000 Implemented
CO0235 # 09 Y:1992 09 1992 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $18,740 $57,080 Implemented
CO0234 # 01 Y:1992 01 1992 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $810 $250 Implemented
CO0234 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,000 $230 Implemented
CO0234 # 03 Y:1992 03 1992 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $505 $150 Implemented
CO0234 # 04 Y:1992 04 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $85 $10,700 Implemented
CO0234 # 05 Y:1992 05 1992 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $390 $1,380 Implemented
CO0234 # 06 Y:1992 06 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $360 $1,480 Implemented
CO0231 # 01 Y:1992 01 1992 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,430 $250 Implemented
CO0231 # 02 Y:1992 02 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $150 $2,850 Implemented
CO0231 # 03 Y:1992 03 1992 INSULATE BARE EQUIPMENT $3,410 $3,200 Implemented
CO0231 # 04 Y:1992 04 1992 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $10,064 $12,670 Implemented
CO0231 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $460 $530 Implemented
CO0231 # 06 Y:1992 06 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $290 $350 Implemented
CO0231 # 07 Y:1992 07 1992 USE POWER DURING OFF-PEAK PERIODS $920 $1,500 Implemented
CO0231 # 08 Y:1992 08 1992 INCREASE AMOUNT OF CONDENSATE RETURNED $1,880 $5,000 Implemented
CO0229 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,221 $0 Implemented
CO0229 # 02 Y:1991 02 1991 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,750 $1,050 Implemented
CO0229 # 03 Y:1991 03 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $390 $200 Implemented
CO0229 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $721 $750 Implemented
CO0229 # 05 Y:1991 05 1991 RECOVER WASTE HEAT FROM EQUIPMENT $400 $450 Implemented