IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

266

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0605 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $10,260 $29,000 Not Implemented
CO0604 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,080 $68,340 Not Implemented
CO0604 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,820 $310 Implemented
CO0604 # 03 Y:2007 03 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $27,400 $2,500 Implemented
CO0604 # 02 Y:2007 02 2007 DIRECT WARMEST AIR TO COMBUSTION INTAKE $112,000 $18,430 Not Implemented
CO0604 # 01 Y:2007 01 2007 IMPROVE COMBUSTION CONTROL CAPABILITY $140,220 $500,000 Not Implemented
CO0603 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,160 $90 Not Implemented
CO0603 # 03 Y:2007 03 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,750 $71,440 Implemented
CO0603 # 02 Y:2007 02 2007 IMPROVE COMBUSTION CONTROL CAPABILITY $121,430 $100,000 Not Implemented
CO0603 # 01 Y:2007 01 2007 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $996,440 $366,170 Not Implemented
CO0591 # 07 Y:2006 07 2006 DISCONNECT BALLASTS $310 $110 Implemented
CO0591 # 06 Y:2006 06 2006 INSTALL OCCUPANCY SENSORS $1,350 $1,290 Not Implemented
CO0591 # 05 Y:2006 05 2006 USE SOLAR HEAT TO MAKE ELECTRICTY $3,900 $32,600 Not Implemented
CO0591 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,680 $5,290 Not Implemented
CO0591 # 03 Y:2006 03 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $260 $30 Not Implemented
CO0591 # 02 Y:2006 02 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $610 $0 Implemented
CO0591 # 01 Y:2006 01 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,430 $200 Implemented
CO0590 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,940 $70,090 Not Implemented
CO0590 # 01 Y:2006 01 2006 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,450 $770 Not Implemented
CO0590 # 02 Y:2006 02 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $2,900 $1,320 Not Implemented
CO0590 # 03 Y:2006 03 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,660 $100 Implemented
CO0590 # 04 Y:2006 04 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $560 $658 Implemented
CO0590 # 05 Y:2006 05 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,880 $0 Not Implemented
CO0590 # 06 Y:2006 06 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $670 $1,390 Not Implemented
CO0590 # 07 Y:2006 07 2006 ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES $560 $500 Implemented