Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,456
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0420 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,225 | $29,780 | Implemented |
CO0420 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,550 | $11,840 | Implemented |
CO0420 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,310 | $330 | Implemented |
CO0420 # 04 Y:1998 | 04 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,020 | $0 | Not Implemented |
CO0417 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,680 | $1,230 | Implemented |
CO0417 # 02 Y:1998 | 02 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $155 | $227 | Implemented |
CO0417 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $860 | $50 | Implemented |
CO0417 # 04 Y:1998 | 04 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $390 | $0 | Implemented |
CO0417 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $350 | $420 | Implemented |
CO0417 # 06 Y:1998 | 06 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,560 | $0 | Not Implemented |
CO0417 # 07 Y:1998 | 07 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $630 | $0 | Not Implemented |
CO0417 # 08 Y:1998 | 08 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $148,000 | $560 | Implemented |
CO0417 # 09 Y:1998 | 09 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $119,000 | $55,330 | Implemented |
CO0417 # 10 Y:1998 | 10 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $61,000 | $0 | Not Implemented |
CO0416 # 01 Y:1998 | 01 | 1998 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,840 | $6,600 | Not Implemented |
CO0416 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $490 | $0 | Not Implemented |
CO0416 # 03 Y:1998 | 03 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,060 | $0 | Not Implemented |
CO0416 # 04 Y:1998 | 04 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $69,150 | $75,000 | Not Implemented |
CO0415 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,850 | $3,500 | n/a |
CO0415 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $586 | $334 | n/a |
CO0415 # 03 Y:1998 | 03 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $810 | $1,580 | n/a |
CO0415 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $700 | $1,250 | n/a |
CO0415 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $100 | $238 | n/a |
CO0415 # 06 Y:1998 | 06 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $4,830 | $2,450 | n/a |
CO0415 # 07 Y:1998 | 07 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $420 | $0 | n/a |