Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
159
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0152 # 07 Y:2015 | 07 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $57,540 | $1,325,000 | Implemented |
DL0152 # 01 Y:2015 | 01 | 2015 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $49,150 | $85,250 | Not Implemented |
DL0152 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,400 | $46,500 | Not Implemented |
DL0152 # 06 Y:2015 | 06 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,980 | $92,000 | Not Implemented |
DL0152 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,300 | $34,100 | Not Implemented |
DL0152 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,290 | $69,750 | Implemented |
DL0152 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,330 | $164,300 | Implemented |
DL0151 # 01 Y:2015 | 01 | 2015 | USE CORRECT SIZE STEAM TRAPS | $12,870 | $2,380 | Not Implemented |
DL0151 # 07 Y:2015 | 07 | 2015 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,970 | $4,480 | Not Implemented |
DL0151 # 03 Y:2015 | 03 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $60,250 | $20,000 | Not Implemented |
DL0151 # 02 Y:2015 | 02 | 2015 | MINIMIZE OVERFLOWS BY INSTALLING LEVEL CONTROLS | $37,680 | $12,400 | Not Implemented |
DL0151 # 04 Y:2015 | 04 | 2015 | OPERATE BOILERS ON HIGH FIRE SETTING | $10,860 | $4,610 | Not Implemented |
DL0151 # 05 Y:2015 | 05 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $7,730 | $11,520 | Not Implemented |
DL0151 # 08 Y:2015 | 08 | 2015 | MINIMIZE WATER USAGE | $80,640 | $200,250 | Not Implemented |
DL0151 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,550 | $14,400 | Not Implemented |
DL0150 # 05 Y:2015 | 05 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,075 | $19,740 | Not Implemented |
DL0150 # 06 Y:2015 | 06 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $13,240 | $62,400 | Not Implemented |
DL0150 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,920 | $500 | Not Implemented |
DL0150 # 08 Y:2015 | 08 | 2015 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $7,020 | $58,500 | Not Implemented |
DL0150 # 03 Y:2015 | 03 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $760 | $560 | Not Implemented |
DL0150 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,720 | $18,100 | Not Implemented |
DL0150 # 04 Y:2015 | 04 | 2015 | INSTALL REPLACEMENT DOORS | $2,450 | $7,800 | Not Implemented |
DL0150 # 01 Y:2015 | 01 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $780 | $0 | Not Implemented |
DL0149 # 01 Y:2015 | 01 | 2015 | INSULATE BARE EQUIPMENT | $15,210 | $630 | Not Implemented |
DL0149 # 02 Y:2015 | 02 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,780 | $0 | Implemented |