Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
838
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0146 # 01 Y:1999 | 01 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,610 | $5,010 | Not Implemented |
DS0146 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $440 | $540 | Implemented |
DS0146 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $561 | $364 | Not Implemented |
DS0146 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $2,488 | $856 | Implemented |
DS0146 # 05 Y:1999 | 05 | 1999 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $16,231 | $8,361 | Not Implemented |
DS0146 # 06 Y:1999 | 06 | 1999 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,235 | $2,407 | Not Implemented |
DS0146 # 07 Y:1999 | 07 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,185 | $4,480 | Not Implemented |
DS0146 # 08 Y:1999 | 08 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $3,008 | $240 | Not Implemented |
DS0145 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,985 | $8 | Implemented |
DS0145 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,434 | $462 | Implemented |
DS0145 # 03 Y:1999 | 03 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $15,332 | $945 | Not Implemented |
DS0144 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,077 | $438 | Implemented |
DS0144 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $567 | $259 | Implemented |
DS0144 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $705 | $216 | Not Implemented |
DS0144 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,642 | $725 | Implemented |
DS0144 # 05 Y:1999 | 05 | 1999 | BURN WASTE OIL FOR HEAT | $1,318 | $1,695 | Not Implemented |
DS0144 # 06 Y:1999 | 06 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,225 | $1,350 | Implemented |
DS0144 # 07 Y:1999 | 07 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $286 | $0 | Implemented |
DS0136 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $1,047 | $1,960 | Implemented |
DS0136 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,330 | $29,424 | Implemented |
DS0136 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $1,921 | $1,137 | Implemented |
DS0136 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $2,815 | $2,459 | Implemented |
DS0136 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $123 | $91 | Implemented |
DS0136 # 06 Y:1999 | 06 | 1999 | UPGRADE OBSOLETE EQUIPMENT | $3,713 | $7,827 | Implemented |
DS0136 # 07 Y:1999 | 07 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $924 | $1,000 | Implemented |