Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,832

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0181 # 02 Y:1983 02 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,422 $9,000 Not Implemented
GT0181 # 03 Y:1983 03 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,800 $65,900 Not Implemented
GT0181 # 04 Y:1983 04 1983 OPTIMIZE PLANT POWER FACTOR $5,360 $12,000 Not Implemented
GT0181 # 05 Y:1983 05 1983 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,800 $1,000 Not Implemented
GT0175 # 01 Y:1983 01 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,900 $12,800 Not Implemented
GT0174 # 01 Y:1983 01 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,771 $49,000 Not Implemented
GT0174 # 02 Y:1983 02 1983 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $382 $200 Not Implemented
GT0174 # 03 Y:1983 03 1983 REPAIR AND ELIMINATE STEAM LEAKS $334 $100 Not Implemented
GT0174 # 04 Y:1983 04 1983 INSULATE BARE EQUIPMENT $225 $133 Not Implemented
GT0174 # 05 Y:1983 05 1983 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $148 $85 Not Implemented
GT0177 # 01 Y:1983 01 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $48,100 $500 Not Implemented
GT0177 # 02 Y:1983 02 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $31,900 $35,000 Not Implemented
GT0177 # 03 Y:1983 03 1983 INSULATE BARE EQUIPMENT $2,450 $800 Not Implemented
GT0177 # 04 Y:1983 04 1983 MODIFY DYE BECK $100,000 $0 Not Implemented
GT0177 # 05 Y:1983 05 1983 MODIFY DYE BECK $190,000 $213,000 Not Implemented
GT0177 # 06 Y:1983 06 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $13,000 $20,000 Not Implemented
GT0177 # 07 Y:1983 07 1983 MODIFY TEXTILE DRYERS $36,800 $25,000 Not Implemented
GT0177 # 08 Y:1983 08 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,890 $14,342 Not Implemented
GT0177 # 09 Y:1983 09 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $18,200 $89,800 Not Implemented
GT0165 # 01 Y:1983 01 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $19,020 $50 Not Implemented
GT0165 # 02 Y:1983 02 1983 MODIFY DYE BECK $13,400 $0 Not Implemented
GT0165 # 03 Y:1983 03 1983 MODIFY TEXTILE DRYERS $14,070 $0 Not Implemented
GT0165 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,250 $3,560 Not Implemented
GT0165 # 05 Y:1983 05 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,160 $69,135 Not Implemented
GT0165 # 06 Y:1983 06 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,646 $9,000 Not Implemented