Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
273
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0761 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,317 | $66,467 | Implemented |
GT0761 # 09 Y:2003 | 09 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,960 | $0 | Not Implemented |
GT0758 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,720 | $47,268 | Implemented |
GT0758 # 02 Y:2003 | 02 | 2003 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,072 | $12,000 | Implemented |
GT0758 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,895 | $47,736 | n/a |
GT0758 # 04 Y:2003 | 04 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $14,438 | $31,350 | n/a |
GT0758 # 05 Y:2003 | 05 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $322 | $0 | Implemented |
GT0758 # 06 Y:2003 | 06 | 2003 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $28,386 | $12,140 | n/a |
GT0758 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,773 | $6,150 | Not Implemented |
GT0758 # 08 Y:2003 | 08 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $23,420 | $1,850 | Implemented |
GT0754 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $24,451 | $69,000 | Implemented |
GT0754 # 02 Y:2003 | 02 | 2003 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $146,600 | $104,000 | Implemented |
GT0754 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,080 | $0 | Implemented |
GT0754 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $788 | $1,731 | Not Implemented |
GT0754 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $840 | $678 | Implemented |
GT0754 # 06 Y:2003 | 06 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $87,548 | $12,750 | Implemented |
GT0754 # 07 Y:2003 | 07 | 2003 | COVER OPEN TANKS | $16,490 | $6,500 | Not Implemented |
GT0754 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,324 | $2,271 | Implemented |
GT0754 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,607 | $1,414 | Implemented |
GT0754 # 10 Y:2003 | 10 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $26,325 | $5,750 | Not Implemented |
GT0754 # 11 Y:2003 | 11 | 2003 | RECOVER AND REUSE COOLING WATER | $293,681 | $201,600 | Implemented |
GT0759 # 01 Y:2003 | 01 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,870 | $3,000 | Implemented |
GT0759 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $770,950 | $340,200 | Not Implemented |
GT0759 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,765 | $188,200 | Implemented |
GT0759 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $200,910 | $20,900 | n/a |