Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

432

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0224 # 06 Y:1999 06 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $240 $600 n/a
IA0224 # 07 Y:1999 07 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $92 $25 n/a
IA0224 # 08 Y:1999 08 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $301 $0 n/a
IA0224 # 09 Y:1999 09 1999 INSTALL OCCUPANCY SENSORS $70 $466 n/a
IA0224 # 10 Y:1999 10 1999 METER WASTE WATER $672 $255 n/a
IA0224 # 11 Y:1999 11 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,381 $2,400 n/a
IA0210 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,138 $17,423 Implemented
IA0210 # 02 Y:1998 02 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,040 $12,186 Not Implemented
IA0210 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $2,457 $2,793 Implemented
IA0210 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,766 $4,820 Implemented
IA0210 # 05 Y:1998 05 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $134 $282 Implemented
IA0210 # 06 Y:1998 06 1998 $261,385 $19,800 Not Implemented
IA0210 # 07 Y:1998 07 1998 USE RADIANT HEATER FOR SPOT HEATING $2,824 $10,101 Not Implemented
IA0197 # 01 Y:1998 01 1998 $234,000 $280,000 n/a
IA0197 # 02 Y:1998 02 1998 $185,000 $340,000 n/a
IA0197 # 03 Y:1998 03 1998 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $22,403 $27,855 n/a
IA0197 # 04 Y:1998 04 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $9,995 $4,200 n/a
IA0197 # 05 Y:1998 05 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $8,880 $0 n/a
IA0197 # 06 Y:1998 06 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,626 $25 n/a
IA0197 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,902 $13,293 n/a
IA0197 # 08 Y:1998 08 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,437 $4,274 n/a
IA0197 # 09 Y:1998 09 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,886 $200 n/a
IA0197 # 10 Y:1998 10 1998 INSTALL OCCUPANCY SENSORS $667 $931 n/a
IA0195 # 01 Y:1998 01 1998 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $19,062 $6,300 Implemented
IA0195 # 02 Y:1998 02 1998 USE DEMAND CONTROLLER OR LOAD SHEDDER $15,886 $2,000 Implemented