Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
810
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0245 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,424 | $3,164 | Not Implemented |
IA0245 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $791 | $0 | Implemented |
IA0245 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $186 | $25 | Implemented |
IA0245 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $142 | $335 | Not Implemented |
IA0245 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $114 | $113 | Implemented |
IA0245 # 07 Y:2000 | 07 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $97,398 | $100,000 | Implemented |
IA0245 # 08 Y:2000 | 08 | 2000 | USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY | $1,500 | $6,500 | Not Implemented |
IA0245 # 09 Y:2000 | 09 | 2000 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $173 | $0 | Not Implemented |
IA0225 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,393 | $381 | Implemented |
IA0225 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,198 | $9,000 | Not Implemented |
IA0225 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $988 | $0 | Implemented |
IA0225 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $265 | $189 | Implemented |
IA0225 # 05 Y:1999 | 05 | 1999 | INSTALL OCCUPANCY SENSORS | $189 | $798 | Not Implemented |
IA0225 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $183 | $13 | Implemented |
IA0225 # 07 Y:1999 | 07 | 1999 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $55,120 | $2,500 | Not Implemented |
IA0225 # 08 Y:1999 | 08 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $6,890 | $12,000 | Not Implemented |
IA0222 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,656 | $1,064 | Not Implemented |
IA0222 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $561 | $931 | Implemented |
IA0222 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $391 | $33 | Implemented |
IA0222 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $421 | $226 | Implemented |
IA0222 # 05 Y:1999 | 05 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $5,097 | $3,584 | Not Implemented |
IA0222 # 06 Y:1999 | 06 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $3,600 | $900 | Implemented |
IA0222 # 07 Y:1999 | 07 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,900 | $3,000 | Not Implemented |
IA0222 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $199,932 | $425,000 | Implemented |
IA0222 # 09 Y:1999 | 09 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $17,160 | $25,792 | Not Implemented |