IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,660

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0459 # 07 Y:2010 07 2010 REPAIR AND ELIMINATE STEAM LEAKS $700 $1,000 Implemented
IA0459 # 08 Y:2010 08 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,899 $329 Implemented
IA0459 # 09 Y:2010 09 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,256 $500 Implemented
IA0459 # 10 Y:2010 10 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,434 $450 Not Implemented
IA0458 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,473 $1,020 Implemented
IA0458 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $1,769 $2,181 Implemented
IA0458 # 03 Y:2010 03 2010 USE RADIANT HEATER FOR SPOT HEATING $48,853 $11,000 Implemented
IA0458 # 04 Y:2010 04 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,520 $2,139 Not Implemented
IA0458 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $4,683 $2,050 Implemented
IA0458 # 06 Y:2010 06 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,258 $25 Not Implemented
IA0458 # 07 Y:2010 07 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $816 $500 Implemented
IA0458 # 08 Y:2010 08 2010 UTILIZE A LESS EXPENSIVE COOLING METHOD $26,636 $22,000 Implemented
IA0457 # 01 Y:2010 01 2010 USE PHOTOCELL CONTROLS $112 $420 Not Implemented
IA0457 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,596 $995 Implemented
IA0457 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $1,389 $1,210 Implemented
IA0457 # 04 Y:2010 04 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,609 $175 Not Implemented
IA0457 # 05 Y:2010 05 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $871 $22 Implemented
IA0457 # 06 Y:2010 06 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $525 $840 Not Implemented
IA0457 # 07 Y:2010 07 2010 RECOVER WASTE HEAT FROM EQUIPMENT $691 $752 Implemented
IA0457 # 08 Y:2010 08 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,163 $70 Implemented
IA0457 # 09 Y:2010 09 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,214 $2,400 Implemented
IA0457 # 10 Y:2010 10 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $428 $579 Implemented
IA0457 # 11 Y:2010 11 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,841 $1,000 Not Implemented
IA0456 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,544 $16,376 Implemented
IA0456 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,332 $3,835 Not Implemented