Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,057
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0360 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,221 | $2,849 | Not Implemented |
IA0360 # 06 Y:2005 | 06 | 2005 | INSTALL STORM WINDOWS AND DOORS | $2,828 | $4,371 | Implemented |
IA0360 # 07 Y:2005 | 07 | 2005 | MAINTAIN MACHINES TO REDUCE LEAKS | $656 | $147 | Implemented |
IA0360 # 08 Y:2005 | 08 | 2005 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,470 | $400 | Not Implemented |
IA0360 # 09 Y:2005 | 09 | 2005 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $3,570 | $400 | Implemented |
IA0359 # 01 Y:2005 | 01 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $15,800 | $6,352 | Not Implemented |
IA0359 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $774 | $76 | Implemented |
IA0359 # 03 Y:2005 | 03 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,024 | $790 | Implemented |
IA0359 # 04 Y:2005 | 04 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,593 | $500 | Not Implemented |
IA0359 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $518 | $30,000 | Implemented |
IA0359 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $299 | $504 | Implemented |
IA0359 # 07 Y:2005 | 07 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,436 | $1,000 | Implemented |
IA0359 # 08 Y:2005 | 08 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $3,866 | $1,223 | Not Implemented |
IA0354 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $530 | $60 | Not Implemented |
IA0354 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,722 | $207 | Implemented |
IA0354 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $561 | $238 | Implemented |
IA0354 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $389 | $710 | Implemented |
IA0354 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $973 | $1,626 | Implemented |
IA0354 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $885 | $2,484 | Implemented |
IA0343 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,846 | $446 | Implemented |
IA0343 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,120 | $1,866 | Not Implemented |
IA0343 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $125 | $70 | Implemented |
IA0343 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,173 | $7,306 | Implemented |
IA0343 # 05 Y:2004 | 05 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $817 | $1,230 | Not Implemented |
IA0343 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,859 | $9,696 | Not Implemented |