Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
148
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0421 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $950 | $2,575 | Implemented |
IA0421 # 07 Y:2007 | 07 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,093 | $1,800 | Implemented |
IA0421 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $5,635 | $651 | Not Implemented |
IA0421 # 04 Y:2007 | 04 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,109 | $4,080 | Implemented |
IA0421 # 05 Y:2007 | 05 | 2007 | MODIFY STARTUP/SHUTDOWN TIMES | $2,951 | $500 | Implemented |
IA0421 # 08 Y:2007 | 08 | 2007 | MINIMIZE WATER USAGE | $10,056 | $400 | Implemented |
IA0421 # 01 Y:2007 | 01 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $5,499 | $675 | Implemented |
IA0421 # 06 Y:2007 | 06 | 2007 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,749 | $60 | Implemented |
IA0419 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,450 | $1,200 | Implemented |
IA0419 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $678 | $25 | Implemented |
IA0419 # 08 Y:2007 | 08 | 2007 | OPTIMIZE PLANT POWER FACTOR | $19,032 | $19,062 | Not Implemented |
IA0419 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,055 | $500 | Implemented |
IA0419 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,515 | $7,460 | Not Implemented |
IA0419 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $758 | $1,001 | Implemented |
IA0419 # 09 Y:2007 | 09 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,583 | $3,300 | Implemented |
IA0419 # 04 Y:2007 | 04 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,431 | $174 | Not Implemented |
IA0419 # 01 Y:2007 | 01 | 2007 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,302 | $1,140 | Not Implemented |
IA0419 # 10 Y:2007 | 10 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,325 | $800 | Implemented |
IA0417 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,956 | $13,071 | Not Implemented |
IA0417 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,598 | $46,276 | Not Implemented |
IA0417 # 04 Y:2007 | 04 | 2007 | ADD AREA LIGHTING SWITCHES | $7,664 | $1,875 | Not Implemented |
IA0417 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,033 | $3,978 | Not Implemented |
IA0417 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,044 | $2,000 | Not Implemented |
IA0417 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,650 | $1,078 | Not Implemented |
IA0416 # 08 Y:2007 | 08 | 2007 | INSTALL OCCUPANCY SENSORS | $1,065 | $1,694 | Implemented |