IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

442

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0195 # 09 Y:2017 09 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,417 $5,650 Implemented
IC0195 # 10 Y:2017 10 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,782 $11,163 Implemented
IC0195 # 11 Y:2017 11 2017 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $697,569 $2,619,820 Not Implemented
IC0194 # 01 Y:2017 01 2017 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $124,626 $220,275 Implemented
IC0194 # 02 Y:2017 02 2017 OPTIMIZE PLANT POWER FACTOR $87,344 $137,763 Implemented
IC0194 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $20,467 $8,000 Not Implemented
IC0194 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,741 $8,162 Not Implemented
IC0190 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $537 $695 n/a
IC0190 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,115 $3,977 n/a
IC0190 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $963 $1,463 n/a
IC0190 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,842 $32,631 n/a
IC0190 # 05 Y:2011 05 2011 INSULATE BARE EQUIPMENT $766 $350 n/a
IC0190 # 06 Y:2011 06 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,423 $2,049 n/a
IC0190 # 07 Y:2011 07 2011 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $6,206 $11,658 n/a
IC0190 # 08 Y:2011 08 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $26,660 $128,000 n/a
IC0190 # 09 Y:2011 09 2011 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,770 $140 n/a
IC0190 # 10 Y:2011 10 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $289 $0 n/a
IC0188 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,742 $44,268 Not Implemented
IC0188 # 02 Y:2011 02 2011 INSTALL OCCUPANCY SENSORS $244 $541 Not Implemented
IC0188 # 03 Y:2011 03 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $9,096 $0 n/a
IC0188 # 04 Y:2011 04 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $285 $0 n/a
IC0188 # 05 Y:2011 05 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $422 $0 n/a
IC0188 # 06 Y:2011 06 2011 REPAIR AND ELIMINATE STEAM LEAKS $3,582 $690 n/a
IC0188 # 07 Y:2011 07 2011 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $6,453 $0 n/a
IC0159 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,803 $27,853 Not Implemented