Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,344
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0242 # 11 Y:1988 | 11 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $107 | $0 | Implemented |
KU0241 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $10,902 | $0 | Implemented |
KU0241 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $15,123 | $6,000 | Implemented |
KU0241 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,831 | $3,786 | Implemented |
KU0241 # 04 Y:1987 | 04 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,027 | $7,700 | Implemented |
KU0241 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,422 | $0 | Implemented |
KU0241 # 06 Y:1987 | 06 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,159 | $500 | Implemented |
KU0237 # 04 Y:1987 | 04 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $407 | $250 | Implemented |
KU0237 # 06 Y:1987 | 06 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,203 | $200 | Implemented |
KU0237 # 08 Y:1987 | 08 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $519 | $0 | Implemented |
KU0237 # 10 Y:1987 | 10 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $3,307 | $157 | Implemented |
KU0238 # 03 Y:1987 | 03 | 1987 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $142 | $0 | Implemented |
KU0238 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $178 | $100 | Implemented |
KU0238 # 05 Y:1987 | 05 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $108 | $0 | Implemented |
KU0239 # 01 Y:1987 | 01 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $5,811 | $300 | Implemented |
KU0239 # 03 Y:1987 | 03 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $392 | $0 | Implemented |
KU0239 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $410 | $79 | Implemented |
KU0239 # 06 Y:1987 | 06 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $222 | $50 | Implemented |
KU0239 # 08 Y:1987 | 08 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $143 | $0 | Implemented |
KU0240 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $953 | $0 | Implemented |
KU0232 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,464 | $0 | Implemented |
KU0232 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $572 | $100 | Implemented |
KU0232 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $170 | $0 | Implemented |
KU0232 # 05 Y:1987 | 05 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $158 | $40 | Implemented |
KU0233 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,637 | $2,246 | Implemented |