Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,217

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0352 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,322 $0 Implemented
KU0352 # 07 Y:1991 07 1991 DIRECT WARMEST AIR TO COMBUSTION INTAKE $735 $2,200 Implemented
KU0352 # 08 Y:1991 08 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $344 $0 Implemented
KU0353 # 01 Y:1991 01 1991 USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY $26,522 $0 Implemented
KU0353 # 02 Y:1991 02 1991 RECOVER AND REUSE COOLING WATER $603 $0 Implemented
KU0353 # 03 Y:1991 03 1991 RECOVER WASTE HEAT FROM EQUIPMENT $2,291 $2,400 Implemented
KU0353 # 04 Y:1991 04 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $752 $120 Implemented
KU0353 # 05 Y:1991 05 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $386 $420 Implemented
KU0353 # 06 Y:1991 06 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $315 $175 Implemented
KU0353 # 07 Y:1991 07 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $297 $1,000 Implemented
KU0353 # 08 Y:1991 08 1991 INSTALL SET-BACK TIMERS $1,871 $300 Implemented
KU0353 # 09 Y:1991 09 1991 REDUCE GLAZED AREAS IN BUILDINGS $1,259 $1,105 Implemented
KU0341 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $2,057 $600 Not Implemented
KU0341 # 02 Y:1991 02 1991 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $3,592 $400 Not Implemented
KU0341 # 03 Y:1991 03 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,117 $950 Not Implemented
KU0341 # 04 Y:1991 04 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,453 $9,300 Not Implemented
KU0341 # 05 Y:1991 05 1991 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $1,435 $800 Not Implemented
KU0341 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,048 $570 Not Implemented
KU0341 # 07 Y:1991 07 1991 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $2,561 $1,975 Not Implemented
KU0341 # 08 Y:1991 08 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,102 $800 Not Implemented
KU0336 # 01 Y:1991 01 1991 RECOVER WASTE HEAT FROM EQUIPMENT $21,491 $19,500 Implemented
KU0336 # 02 Y:1991 02 1991 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $15,055 $18,000 Implemented
KU0336 # 03 Y:1991 03 1991 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $12,114 $27,600 Implemented
KU0336 # 04 Y:1991 04 1991 RECOVER WASTE HEAT FROM EQUIPMENT $9,818 $3,800 Implemented
KU0336 # 05 Y:1991 05 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $22,099 $22,000 Implemented