Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
112
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0297 # 06 Y:1989 | 06 | 1989 | TREAT AND REUSE RINSE WATERS | $15,540 | $9,000 | Implemented |
KU0297 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $218 | $119 | Implemented |
KU0293 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $227 | $118 | Implemented |
KU0293 # 06 Y:1989 | 06 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $40,497 | $0 | Not Implemented |
KU0293 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $528 | $130 | Implemented |
KU0293 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,638 | $450 | Implemented |
KU0293 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $360 | $41 | Implemented |
KU0293 # 04 Y:1989 | 04 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $345 | $0 | Not Implemented |
KU0292 # 05 Y:1989 | 05 | 1989 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $167 | $120 | Implemented |
KU0288 # 03 Y:1989 | 03 | 1989 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $643 | $2,900 | Implemented |
KU0292 # 04 Y:1989 | 04 | 1989 | INSTALL SET-BACK TIMERS | $3,496 | $1,000 | Implemented |
KU0288 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,064 | $1,200 | Implemented |
KU0288 # 04 Y:1989 | 04 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $584 | $1,800 | Not Implemented |
KU0289 # 01 Y:1989 | 01 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,155 | $1,600 | Implemented |
KU0289 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,454 | $2,880 | Implemented |
KU0289 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,861 | $8,150 | Not Implemented |
KU0289 # 04 Y:1989 | 04 | 1989 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $6,782 | $7,500 | Not Implemented |
KU0289 # 05 Y:1989 | 05 | 1989 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $5,839 | $12,000 | Not Implemented |
KU0289 # 06 Y:1989 | 06 | 1989 | INSTALL SET-BACK TIMERS | $228 | $40 | Implemented |
KU0292 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $10,146 | $800 | Implemented |
KU0292 # 02 Y:1989 | 02 | 1989 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $751 | $700 | Not Implemented |
KU0292 # 03 Y:1989 | 03 | 1989 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $591 | $1,350 | Not Implemented |
KU0292 # 06 Y:1989 | 06 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,284 | $3,144 | Not Implemented |
KU0288 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,193 | $500 | Implemented |
KU0259 # 08 Y:1988 | 08 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $225 | $150 | Implemented |