Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0353 # 06 Y:1991 | 06 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $315 | $175 | Implemented |
KU0353 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $297 | $1,000 | Implemented |
KU0353 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $1,871 | $300 | Implemented |
KU0353 # 09 Y:1991 | 09 | 1991 | REDUCE GLAZED AREAS IN BUILDINGS | $1,259 | $1,105 | Implemented |
KU0341 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $2,057 | $600 | Not Implemented |
KU0341 # 02 Y:1991 | 02 | 1991 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $3,592 | $400 | Not Implemented |
KU0341 # 03 Y:1991 | 03 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,117 | $950 | Not Implemented |
KU0341 # 04 Y:1991 | 04 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,453 | $9,300 | Not Implemented |
KU0341 # 05 Y:1991 | 05 | 1991 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,435 | $800 | Not Implemented |
KU0341 # 06 Y:1991 | 06 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,048 | $570 | Not Implemented |
KU0341 # 07 Y:1991 | 07 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,561 | $1,975 | Not Implemented |
KU0341 # 08 Y:1991 | 08 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,102 | $800 | Not Implemented |
KU0336 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,491 | $19,500 | Implemented |
KU0336 # 02 Y:1991 | 02 | 1991 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $15,055 | $18,000 | Implemented |
KU0336 # 03 Y:1991 | 03 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,114 | $27,600 | Implemented |
KU0336 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,818 | $3,800 | Implemented |
KU0336 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $22,099 | $22,000 | Implemented |
KU0336 # 06 Y:1991 | 06 | 1991 | REDESIGN PROCESS | $10,585 | $25,200 | Implemented |
KU0336 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,650 | $17,100 | Implemented |
KU0336 # 08 Y:1991 | 08 | 1991 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,112 | $0 | Implemented |
KU0336 # 09 Y:1991 | 09 | 1991 | INSTALL SET-BACK TIMERS | $899 | $1,000 | Implemented |
KU0336 # 10 Y:1991 | 10 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $366 | $0 | Implemented |
KU0336 # 11 Y:1991 | 11 | 1991 | RECOVER AND REUSE COOLING WATER | $9,720 | $5,340 | Implemented |
KU0334 # 01 Y:1991 | 01 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $10,153 | $1,800 | Implemented |
KU0334 # 02 Y:1991 | 02 | 1991 | SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY | $336 | $40 | Implemented |