Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,537
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0533 # 03 Y:1999 | 03 | 1999 | USE SYNTHETIC LUBRICANT | $2,830 | $5,010 | Not Implemented |
KU0533 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,580 | $160 | Not Implemented |
KU0533 # 01 Y:1999 | 01 | 1999 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,950 | $9,500 | Not Implemented |
KU0532 # 08 Y:1999 | 08 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $2,620 | $800 | Implemented |
KU0532 # 07 Y:1999 | 07 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $12,150 | $11,640 | Not Implemented |
KU0532 # 06 Y:1999 | 06 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,410 | $14,000 | Not Implemented |
KU0532 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $360 | Implemented |
KU0532 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $700 | $450 | Implemented |
KU0532 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,060 | $12,170 | Implemented |
KU0532 # 02 Y:1999 | 02 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,040 | $20,000 | Implemented |
KU0532 # 01 Y:1999 | 01 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,410 | $17,000 | Not Implemented |
KU0531 # 06 Y:1999 | 06 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $91,030 | $325,000 | Not Implemented |
KU0531 # 05 Y:1999 | 05 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $600 | $0 | Not Implemented |
KU0531 # 04 Y:1999 | 04 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,370 | $110 | Not Implemented |
KU0531 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,520 | $2,670 | Not Implemented |
KU0531 # 02 Y:1999 | 02 | 1999 | USE SYNTHETIC LUBRICANT | $2,350 | $3,690 | Not Implemented |
KU0531 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $8,350 | $9,600 | Not Implemented |
KU0530 # 05 Y:1999 | 05 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $11,600 | $10,670 | n/a |
KU0530 # 04 Y:1999 | 04 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $55,080 | $1,380 | n/a |
KU0530 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $620 | $730 | n/a |
KU0530 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $900 | $520 | n/a |
KU0530 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,910 | $8,800 | n/a |
KU0529 # 04 Y:1999 | 04 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,840 | $840 | Implemented |
KU0529 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $360 | $700 | Implemented |
KU0529 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $930 | Implemented |